Maintenance
6006190_a – 20.05.2022
EN
6.2.2 Replacing filter filling (with recirculated air
mode)
Odours are trapped in the filter filling in the recirculated air
filter. The odour-free, cleaned room air is fed back into the
room.
Recirculated air filters are maintenance-free for up to two
years. Then filter filling must be replaced at regular intervals.
Maintenance intervals
yWhen the control indicator blinks - every 1000 fan
operating hours.
D“4.2.5 Filter filling indicator (page 28).
yWith odours in the exhaust air.
yWith daily use, after 24 months at the latest.
yWith occasional use, after 36 months at the latest.
DATTENTION!
Danger of property damage through falling parts!
When working on the device, parts of the device or tools
could fall and damage the kitchen equipment.
Protect the cooled hob and other surfaces in the cooking
area (e.g. with thick cardboard).
Move the device parts with the utmost caution.
Lift the filter at least 30 mm.
Remove the filter to the front.
The replacement of the filter filling is carried out as
described in the associated instructions.
Change the filter filling.
Clean the filter from the outside (e.g. through extraction
with a vacuum cleaner).
Fit the filter again.
D“3.5.7 Installing the recirculated air filter BUF 125 +”
(page 20).
6.3 Fault rectification
Possible faults are described below:
Description of the fault.
yPossible cause.
Remedy.
Fan and lighting do not work.
yNo power supply.
Check that the all-pole mains switch is connected.
Switch the mains switch on.
yThe breaker may have been tripped or is defective.
Check to see if the breaker has tripped.
If you use electric circuit breakers, turn the circuit
breaker on again.
For other types of fuse, consult a qualified electrician.
The fan does not work.
yThe device is not switched on.
Check all power levels.
D“4.2.1 Normal operation (page 26).
yThe device is connected to a window contact switch and
the window is closed.
Open the window.
yThe device is connected to a safety device. The safety
device detects a critical under-pressure.
Open a window.
Wait until the air pressure returns to normal.
The lighting does not work.
yThe device software requires a restart.
Interrupt the power supply for approx. 10 seconds.
yThe lamp has blown.
Please consult your dealer or customer services.
Poor device performance.
yThe recirculated air filter is clogged.
Replace the filter filling of the recirculated air filter.
D“6.2.2 Replacing filter filling (with recirculated air
mode)” (page 31).
yThe exhaust pipe was not properly connected or installed.
Please consult your dealer or customer services.
yIn the case of devices with recirculated air mode, there is
a lack of sufficient ventilation.
Make sure that the ventilation slots (e.g. stainless steel
cover grill) are available, clear and sufficiently large
(cross-section larger than 300 cm2).
Smells occur during operation.
yThe filter filling is used up.
Change the filter filling.
D“6.2.2 Replacing filter filling (with recirculated air
mode)” (page 31).
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BEH 90 FLU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BEH 90 FLU in the language / languages: English as an attachment in your email.

The manual is 17.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BEH 90 FLU

Berbel BEH 90 FLU User Manual - German - 36 pages

Berbel BEH 90 FLU User Manual - Dutch - 36 pages

Berbel BEH 90 FLU User Manual - French - 36 pages

Berbel BEH 90 FLU User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info