Installation
6006190_a – 20.05.2022
3.5.6 Connect accessories
Depending on the installation situation, available accessories
may be connected to the hood, e.g.:
yWall box
yWindow contact switch
yControl flap
yRecirculated air filter permalyt
Observe the instructions for the accessories.
DATTENTION!
Danger of damage due to improper connection!
Applied voltage or defective connections can result in
damage to the electronics.
Ensure that the power supply is switched off and remains
so.
Ensure correct assignment of the connections.
Make sure that the accessories plugs are fully inserted.
A
B
C
A Jack socket - for connection of wall box, control flap or
recirculated air filter permalyt.
B DC power socket - for connecting a window contact
switch.
C Connection socket (RJ45) – BUS interface for connection
with special accessories of the manufacturer.
Connection with a PC or other devices is not permitted.
Wall box
yThe wall box is closed when the control contacts are
open.
yThe wall box is open when the control contacts are
closed.
Window contact switch
yThe hood‘s fan is only operational when the window is
open.
Safety device
yThe hood‘s fan is only operational when no critical under-
pressure is determined in the room.
Connect any available accessories.
Route the cable such that it is not kinked, crushed or
damaged and so that it will not get in the way when
replacing the filter filling.
3.5.7 Installing the recirculated air filter BUF125+
Installation of the filter takes place adjacent to the fan
housing, on top of the hood body. The filter can be
positioned precisely.
Insert the fan insert grid in the fan outlet.
Align the recirculated air filter.
Fit the filter in front of the fan outlet.
Make sure that the filter is correctly positioned.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BEH 90 FLU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BEH 90 FLU in the language / languages: English as an attachment in your email.

The manual is 17.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BEH 90 FLU

Berbel BEH 90 FLU User Manual - German - 36 pages

Berbel BEH 90 FLU User Manual - Dutch - 36 pages

Berbel BEH 90 FLU User Manual - French - 36 pages

Berbel BEH 90 FLU User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info