BENNING PV 1-1
15
A R
PE
voltage polarity indication, indicates the polarity of the DC voltage at the 4 mm test
sockets K and L. For AC voltage, “+” and ““ are displayed alternately.
B
Current clamp measurement enabled
C
Ω
NULL
R
PE
null offset, is displayed in case of a compensation (null balance) of the measuring
lead resistance
D Attention, hot surface! If the symbol is displayed, immediately disconnect the
BENNING PV 1-1 from the PV generator. Connect the BENNING PV 1-1 only after the
symbol has disappeared.
E Polarity indication, indicates the polarity of the DC voltage at the PV test sockets
9
and
J
F
c
Attention, dangerous voltage has been detected
G R
PE
LOCK, enabled, if a continuous R
PE
measurement has been activated
H
m
Attention, if this symbol is activated, observe the instructions contained in the operating
manual in order to avoid danger.
I R
ISO
(pass)/ (fail), indicates whether the measured insulating resistance is within the
preset limiting values
J Selection of the insulation test voltage, displays the testing voltage of the insulating re-
sistance measurement
K Error, see specific error codes for further details (More details in chapter 9.1. “Error codes”)
L STORE, LCD data are stored in the internal memory
M RECALL, stored LCD data are loaded from the internal memory
N Storage location indicator, indicates the current storage location (1…200)
O Voltage / current deviation, indicates a deviation of the measured open-circuit voltage and
short-circuit current values of more or less than 5 %
P Battery symbol, is displayed to indicate discharged batteries
5. General information
The BENNING PV 1-1 is intended for electrical safety tests according to VDE 0126-23 (DIN EN
62446).
The BENNING PV 1-1 automatically tests connected PV modules or PV strings. All measuring
results are displayed on the large LC display.
- At full battery capacity, the BENNING PV 1-1 allows to carry out up to 3000 automatic mea-
surements of Vo/c, Is/c and R
ISO
(500 V).
- Appliance dimensions:
(L x W x H) = 270 x 115 x 55 mm
- Appliance weight: 2600 g
6. Environment conditions:
- The BENNING PV 1-1 is intended for making measurements in dry environment.
- Maximum barometric elevation for making measurements: 2000 m,
- Over voltage category/ Siting category: IEC/ EN 61010-1 → 1000 V category I (this apply to
the red
9
and black
J
PV test socket),
- Over voltage category/ Siting category: IEC/ EN 61010-1 → 300 V category III (this apply to
the red L and black K 4 mm test socket),
- Contamination class: 2,
- Protection Class: IP 50 (DIN VDE 0470-1 IEC/ EN 60529)
IP 50 means: Dustproof, (5 - first index). No protection against water, (0 - second index).
- EMC: IEC/ EN 61326,
- Operating temperature and relative humidity:
For operating temperature from 0 °C to 30 °C: relative humidity less than 80 %
For operating temperatures from 31 °C to 40 °C: relative humidity less than 75 %
- Storage temperature: The BENNING PV 1-1 can be stored at any temperature in the range
from - 25 °C to + 65 °C (relative humidity from 0 to 90 %). The battery should be taken out of
the instrument for storage.
7. Electrical specifications
Note: The measuring precision is specied as the sum of
- a relative fraction of the measured value and
- a number of digits (counting steps of the least signicant digit).
This specied measuring precision is valid for temperatures in the range from 18 °C to 30 °C and
relative humidity less than 80 %.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning PV 1.1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning PV 1.1 in the language / languages: English, German as an attachment in your email.

The manual is 10,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Benning PV 1.1

Benning PV 1.1 Quick start guide - Dutch, French, Italian, Spanish - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info