BENNING IT 130 Technische Daten
- 69 -
8 Technische Daten
8.1 Isolationswiderstand
Isolationswiderstand (Nennspannungen 50 V
DC
, 100 V
DC
und 250 V
DC
)
Messbereich gemäß EN 61557-2: 0,15 M 199,9 M
Messbereich (M)
Auflösung (M)
Genauigkeit
0,00 19,99
0,01
(5 % des Messwertes + 3 Digit)
20,0 99,9
0,1
(10 % des Messwertes)
100,0 199,9
(20 % des Messwertes)
Isolationswiderstand (Nennspannungen 500 V
DC
und 1000 V
DC
)
Messbereich gemäß EN 61557-2: 0,15 M 999 M
Messbereich (M)
Auflösung (M)
Genauigkeit
0,00 19,99
0,01
(5 % des Messwertes + 3 Digit)
20,0 199,9
0,1
(5 % des Messwertes)
200 999
1
(10 % des Messwertes)
Spannung
Messbereich (V)
Auflösung (V)
Genauigkeit
0 1200
1
(3 % des Messwertes + 3 Digit)
Nennspannungen ................................... 50 V
DC
, 100 V
DC
, 250 V
DC
, 500 V
DC
, 1000 V
DC
Leerlaufspannung ................................... -0 %/+20 % der Nennspannung
Messstrom .............................................. min. 1 mA bei R
N
=U
N
1 k/V
Kurzschlussstrom .................................. max. 3 mA
Anzahl möglicher Prüfungen .................. > 1200, bei vollständig geladener Batterie/Akku
Automatische Entladung nach Prüfung.
Die angegebene Genauigkeit gilt bei Verwendung der 3-Leiter-Prüfleitung und bis 100 M bei
Verwendung der Commander-Prüfspitze.
Die angegebene Genauigkeit gilt bis 100 M bei einer relativen Luftfeuchtigkeit > 85 %.
Falls das Prüfgerät feucht wird, kann das Ergebnis beeinträchtigt werden. In diesem Fall wird
empfohlen, das Prüfgerät und sein Zubehör mindestens 24 Stunden lang zu trocknen.
Der maximale Fehler unter Betriebsbedingungen entspricht dem maximalen Fehler unter
Referenzbedingung zuzüglich 5 % des Messwertes.
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning IT 130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning IT 130 in the language / languages: German as an attachment in your email.

The manual is 2,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Benning IT 130

Benning IT 130 User Manual - English - 24 pages

Benning IT 130 Quick start guide - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info