577179
12
Zoom out
Zoom in
Previous page
1/65
Next page
09/ 2013
BENNING CM 3
12
2. Safety instructions
The instrument is built and tested in accordance with
DIN VDE 0411 Part 1/ EN 61010-1
and has left the factory in perfectly safe technical condition.
To preserve this condition and to ensure safe operation of the device, the user
must observe the notes and warnings given in these instructions at all times.
The unit may be used only in power circuits within the over-
voltage category II with a conductor for 600 V max. to earth,
or within overvoltage category III with a conductor for 300 V
against ground.
Remember that work on electrical components of all kinds is
dangerous. Even low voltages of 30 V AC and 60 V DC may be
dangerous to human life.
Before starting the multimeter up, always check it for signs of
damage.
Should it appear that safe operation of the multimeter is no longer possible, it
should be shut down immediately and secured to prevent it being switched on
accidentally.
It may be assumed that safe operation is no longer possible:
- if the instrument shows visible signs of damage, or
- if the multimeter no longer functions, or
- after long periods of storage under unfavourable conditions, or
- after being subjected to rough transport.
3. Contents of delivery
The following items are included in the delivery of a BENNING CM 3 :
3.1 one BENNING CM 3,
3.2 one protective carrying case with velcro fastening,
3.3 one 9-V block battery (built into current clamp ),
3.4 one operating manual.
Note on replaceable parts:
The BENNING CM 3 is powered by one 9-V block battery (IEC 6 LR 61).
4. Tester description
The BENNING CM 3 is a meter with Hall effect and manual range selection.
refertogure1: fronttesterpanel
Thedisplayandoperatingelementsshowningure1aredenotedasfollows:
1
Clamp jaws, for gripping single DC or AC conductors.
2
Current clamp safety guard, protects user from electrical contact.
3
Trigger, to open and close the clamp jaws.
4
Switch, for the HOLD function (retaining function),
- slide the switch to the right to hold the reading on display (the annuncia-
tor H appears in the digital display
8
, and the display is not updated by
subsequent readings),
- slide the switch to the left to resume recording of readings.
5
Adjustment potentiometer (knob). For setting voltage display to nil before
DC current measurements.
6
Switch, for the selection of desired current type (AC - DC).
7
Switch, for range selection (200 A/ 600 A), with annunciator
8
Digital LCD display, shows the following:
- measurement value up to a maximum value of 1999,
- a polarity indicator
- a decimal point,
- low battery symbol,
- the selected current type (alternating voltage / direct voltage),
- the measurement value retained in memory (Hold function).
9
Housing
5. General Specications
5.1 General specications for the BENNING CM 3
5.1.1 The digital display is a 3½ digit liquid crystal display with 14 mm digit
height and automatic decimal point placement. The highest display va-
lue is 1999.
5.1.2 The polarity display
8
isautomatic.Aspositiveisimpliedbythedened
input terminal, only a negative pole will be indicated with „-“ on the jaw of
the clamp.
5.1.3 Overranging is indicated by „1“ or „-1“.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning CM3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning CM3 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 2,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info