11/ 2014
BENNING CM 11
11
- Storage temperature: The BENNING CM 11 can be stored at temperatures between - 10 °C
and + 60 °C, at a relative air humidity lower than 80 % without batteries.
7. Electrical specifications
Note: The measuring precision is specified as the sum of
- a relative fraction of the measured value and
- a number of digits (counting steps of the least significant digit).
This specified measuring precision is valid for temperatures in the range from 23 °C ± 5 °C and
relative humidity less than 80 %.
7.1 DC voltage range
The input resistance is ≥ 1 MΩ.
Measuring range Resolution Measurement accuracy Overload protection
50.00 V 0.01 V ± (1 % of reading + 2 digits) 400 V AC/DC
300.0 V 0.1 V ± (1 % of reading + 2 digits) 400 V AC/DC
7.2 AC voltage range
The measured value is obtained and displayed as real r.m.s. value (True RMS, AC coupling).
Its calibration is adapted to sinusoidal curves. In case of deviations from this curve shape, the
accuracy of the displayed value decreases.
Crest factor < 2.0 up to 100 % of the final measuring range value
Crest factor < 4.0 up to 50 % of the final measuring range value
The input resistance is ≥ 1 MΩ.
Measuring range Resolution Measurement accuracy (40 Hz - 1 kHz) Overload protection
50.00 V 0.01 V ± (1.2 % of reading + 5 digits) 400 V AC/DC
300.0 V 0.1 V ± (1.2 % of reading + 5 digits) 400 V AC/DC
7.3 DC current range
Measuring range Resolution Measurement accuracy Overload protection
300.0 mA 0.1 mA ± (1.0 % of reading + 10 digits) 100 A AC/DC
3.000 A 0.001 A ± (1.0 % of reading + 10 digits) 100 A AC/DC
10.00 A 0.01 A ± (3.0 % of reading + 10 digits) 100 A AC/DC
Influence of geomagnetism: < ± 1.0 mA
Influence of opening and closing the measuring clamp: < ± 1.0 mA
7.4 AC current range
The measured value is obtained and displayed as real r.m.s. value (True RMS, AC coupling).
Its calibration is adapted to sinusoidal curves. In case of deviations from this curve shape, the
accuracy of the displayed value decreases.
Crest factor < 2.0 up to 100 % of the final measuring range value
Crest factor < 4.0 up to 50 % of the final measuring range value
Measuring range Resolution Measurement accuracy (50 Hz - 60 Hz) Overload protection
300.0 mA 0.1 mA ± (1.0 % of reading + 5 digits) 100 A AC/DC
3.000 A 0.001 A ± (1.0 % of reading + 5 digits) 100 A AC/DC
20.00 A 0.01 A ± (1.0 % of reading + 5 digits) 100 A AC/DC
7.5 Resistance range
Open circuit-voltage: approx. 3 V, max. testing current 1 mA
Measuring range Resolution Measurement accuracy (50 Hz - 60 Hz) Overload protection
500.0 Ω 0.1 Ω ± (1 % of reading + 2 digits) 400 V AC/DC
5.000 kΩ 1 Ω ± (1 % of reading + 2 digits) 400 V AC/DC
50.00 kΩ 10 Ω ± (1 % of reading + 2 digits) 400 V AC/DC
500.0 kΩ 100 Ω ± (1 % of reading + 2 digits) 400 V AC/DC
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning CM11.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning CM11.0 in the language / languages: English, German, Dutch, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info