The smoke
appears in the fire
room or in the fuel
container.
Low chimney draught.
Ensure the inspection of the
chimney draught at the service
chimney company. If the draught
value is lower than the required
value (see users manual) the
adjustment of the chimney is
required.
Fire door and/or the
upper boiler cover
and/or the fuel
container cover are not
closed properly.
Close the fire door and/or the
upper cover of the boiler and/or the
fuel container cover.
The sealing gasket at
the fire door or at the
upper boiler cover was
worn out/damaged
Change the sealing gasket.*
The rubber sealing of
the fuel container
cover is damaged.
Change the rubber sealing.*
The container cover is
not tight.
Vertically adjust the latch at the fuel
container cover.
The fuel container is
empty.
Fill the fuel container with the fuel.
The boiler is
soated with
smoke particles in
a short period of
time.
Low amount of
agitated air.
Raise the ventilator capacity (see
Instruction Control Unit manual).
The boiler is
repeatedly overheated
Set the boiler capacity to the
nominal capacity (see Instruction
Control Unit manual).
The grate is full of dust
and ash.
Clean the grate.
The ventilator is
broken.
Change the boiler ventilator.*
The ash at the
grate is sintering.
Other than
recommended fuel was
used for burning.
Fill the container with appropriate
fuel (see chapter 3).
A great quantity
of unburned fuel
appears in the
ashtray.
The fuel dosage is
maladjusted.
Lower the dosage of fuel in the
burner (see the Instruction Control
Unit manual).
The fuel used for
burning is wet.
Fill the container with appropriate
(dry) fuel.
The power of the
ventilator is wrongly
set and the stream of
air blows the fuel out of
the burner.
Lower the ventilator speed (see
Instruction Control Unit manual).
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benekov R16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benekov R16 in the language / languages: English as an attachment in your email.

The manual is 1,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info