- ventilator drive connector
- water circulating pump connector
- de-asher connector
- extraction of combustion gases connector
- automatic ignition connector
- indoor thermostat connector or equithermal regulation connector
- ignition sensor connector
- lambda probe connector
- limit switch of the fuel container cover
Free plug contacts (e.g. for connecting the indoor thermostat, circulation pump etc.) are delivered in a
pack inside the boiler. Before startup, these have to be installed on the switchboard, even if they are not
used.
When installing the connectors, it is necessary to make sure that the right connectors are connected
i.e. it is only allowed to connect plug contacts and plugs with identical symbols.
Prior to connecting the room thermostat or equithermal regulation, it is necessary to remove the jumper
from the connector plug. Only a thermostat with a free non-potential contact (e.g. SIEMENS,
HONEYWELL CM…) can be connected to the room thermostat or equithermal regulation contact. No
foreign voltage may be connected to the terminals.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benekov R100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benekov R100 in the language / languages: English as an attachment in your email.

The manual is 1,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info