ČSN EN 303-5:2013 - Central heating boilers – part 5: Central heating boilers for solid fuel with manual
or automatic supply of fuel with nominal power up to 500 kW - terminology,
requirements, proofing and marking.
The main part of the boiler is the steel body which consists of 4 main units:
- combustion chamber
- combustion chamber base
- heat exchanger
- heat exchanger base.
All parts of the boiler body that separate combustibles from heating water and all base bearings are
made of 5 mm thick steel plates. In the front part of the boiler body, there is a combustion chamber
fitted with a burner, in the back there is a 3-pass heat exchanger. In this device, the heat from the
exhaust gas is transferred to the heating water.
The burner, which is fed from the bottom, is located in the mixer and fitted to the side wall of the base.
It consists of a cast iron elbow (“retort”) and a cast iron grate. The fuel conveyer consists of a fuel
feeding channel and a pipe for supply of burning air. Both channels are connected by a flexible piece
that serves to balance the pressure under the fire place and prevents the smoke from penetrating back
to the fuel container during the burning process.
A ceramic reflector is installed over the burner. This catalyser regulates the exhaust gas stream and
reduces dust. Through the side wall of the combustion chamber, secondary air is led into the reflector
which facilitates complete burning of fuel.
Next to the boiler, the fuel container is situated, which is connected to the worm conveyor. Its capacity
can be extended by installing an additional module (optional). Depending on the position of the
container in relation to the boiler, the boiler is produced in two versions:
right-handed version - the container is situated on the right side of the boiler (from the front
view)
left-handed version - the container is situated on the left side of the boiler (from the front
view)
Behind the fuel container there is an emergency extinguishing system leading into the worm feeder.
The primary combustion air ventilator is placed on the side of the boiler under the fuel container and is
connected to the mixer. The air quantity is regulated by the boiler control unit.
Both heating water input and output for connection to the heating system are situated on the outer side
of the boiler. There are two outlets with G 2“ inner thread. The two outlets with G 3/4“ on the same
boiler side are intended for installation of drain taps - one for the combustion chamber, one for the
tubular heat exchanger. There is a smoke extension piece on the upper rear side of the boiler for the
discharge of combustion products into a chimney.
Device for extraction of combustion gases enhances the chimney draught and forms an integral part of
the boiler.
The boiler body, its cover, and the door are insulated with an insulation material that has no detrimental
effects on health. This insulation diminishes the loss due to heat interchange.
The steel plates are coloured with high quality comaxit paint.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benekov R100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benekov R100 in the language / languages: English as an attachment in your email.

The manual is 1,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info