Bell res Français
Notice d’installation
Modèle : VIEW BELL VERTICAL 3 CF (Centre Fire)
Gaz : GAZ NATUREL
Pays : FR; France / BE; Belgique
Produit identifi cation no : 0063CM3684
Type de d’appareil suivant CE-norm : C11 / C31 / C31S
Catégorie d’appareil : I2E+ gaz naturel G20/G25.3
Débit calorifi que (Supérieur) : 8,3 kW
Puissance nominale (max.) : 6,4 kW
Catégorie de rendement : 1 (85%)
Classe de NOx : 5
Débit gaz (max.) : G20:
0,78 m3
s/hr.
G25.3: 0,82 m3
s/hr.
Pression d’alimentation : G20: 20,0 mbar
G25.3: 25,0 mbar
Pression au brûleur (max.) Chaud : G20: 13,0 mbar(*)
G25.3: 16,0 mbar(*)
Pression au brûleur (max.) Froid : G20: 12,3 mbar(**)
G25.3: 15,3 mbar(**)
Pression au brûleur (min.) : 0,6 mbar(***)
Aération primaire brûleur Arrière : 1x Ø12,0 mm
Aération primaire brûleur Avant : 1x Ø12,0 mm
Bloc de réglage du gaz (télécommande) : Mertik GV 60
Brûleur principal : Centre Fire 295 x 130 mm
Injecteur brûleur Arrière : no 140 (= 1x Ø1,40 mm)
Injecteur brûleur Avant : no 200 (= 1x Ø2,00 mm)
Veilleuse brûleur : SIT 0.145.019
Injecteur veilleuse : no 36 (SIT 0.977.091)
Raccordement au gaz : 3/8” G / Ø12 mm
Raccordement systeme concentrique : Ø100 mm - Ø150 mm ou
Ø130 mm - Ø200 mm
7 FICHE TECHNIQUE ET PRESCRIPTIONS
Regulations d’installation nationales:
FRANCE : Les textes reglémentaires: Les règles de l’art:
- Arrêté du 2 août 1977 - DTU 24.1 (travaux de fumisterie)
- Arrêté du 22 octobre 1969 - DTU 61.1 (installations de gaz)
- Norme NF C 15-100 (installations d’électrique)
BELGIQUE : NBN D-51-003 : Gaz
AREI / RGIE : Électricité
89


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires View Bell Vertical 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires View Bell Vertical 3 in the language / languages: French as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires View Bell Vertical 3

Bellfires View Bell Vertical 3 Installation Guide - English - 100 pages

Bellfires View Bell Vertical 3 User Manual - English - 32 pages

Bellfires View Bell Vertical 3 Installation Guide - German - 116 pages

Bellfires View Bell Vertical 3 User Manual - German - 32 pages

Bellfires View Bell Vertical 3 Installation Guide - Dutch - 100 pages

Bellfires View Bell Vertical 3 User Manual - Dutch - 28 pages

Bellfires View Bell Vertical 3 User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info