3 FAULTS
3.1 POSSIBLE REASONS
Possible reasons for the gas fi re going out are:
The concentric fl ue system is not installed according to one of the methods detailed
in Paragraph 1.6.
An incorrect “fl ue gas restriction plate” is fi tted.
The pilot light extinguishes if fumes are not exhausted or are insuffi ciently
exhausted.
The pilot light is either dirty or defective.
Insuffi cient gas pressure.
(Internal) leak of the concentric fl ue system.
Thermocouple voltage is too low. This is usually caused by insuffi cient heating of the
thermocouple by the pilot light.
Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
Batteries in receiver or remote control are fl at.
3.2 SAFETY MEASURES IN THE APPLIANCE
3.2.1 Thermo-electric pilot light shut off
The appliance is protected by means of a thermo-electric pilot light shut off in the event
of a gas escape from the main burner.
3.2.2 Over pressure safety system
The appliance is fi tted with a patented safety system, whereby the door will extract any
over-pressure that arises in a controlled way. In this, a spring system briefl y causes the
door to hinge forward a few centimetres. A loud noise can occur.
A safety strip limits the maximum degree to which the door can be tilted.
This applies to both doors!
If an over-pressure situation occurs, the appliance should be thoroughly checked by the
installer.
68


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires Vertical Bell Medium Tunnel 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires Vertical Bell Medium Tunnel 3 in the language / languages: English as an attachment in your email.

The manual is 2.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires Vertical Bell Medium Tunnel 3

Bellfires Vertical Bell Medium Tunnel 3 User Manual - English - 32 pages

Bellfires Vertical Bell Medium Tunnel 3 Installation Guide - German - 108 pages

Bellfires Vertical Bell Medium Tunnel 3 User Manual - German - 32 pages

Bellfires Vertical Bell Medium Tunnel 3 Installation Guide - Dutch - 96 pages

Bellfires Vertical Bell Medium Tunnel 3 User Manual - Dutch - 28 pages

Bellfires Vertical Bell Medium Tunnel 3 Installation Guide - French - 96 pages

Bellfires Vertical Bell Medium Tunnel 3 User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info