645672
60
Zoom out
Zoom in
Previous page
1/68
Next page
60
Bell res English
Installation instructions
8 TECHNICAL DETAILS/REGULATIONS
National installation regulations:
Gas safety installation and use regulations 1998 plus all relevant
safety and building regulations concerning fi re installation
Document J: Combustion appliances and fuel storage systems
Model : SMART BELL 75-80 PF (PREMIUM FIRE)
Gas : NATURAL GAS
Country :
GB; G
reat Britain
/IE;
Ireland
Product identifi cation no. : 0063CM3684
Appliance type acc. to CE standard : C11 / C31 / C91
Appliance category : I2H natural gas G20
Nominal heat input : 11.5 kW
(Gross calorifi c value)
Nominal heat output : 8.8 kW
Effi ciency class : 1 (85%)
NOx class : 5
Gas rate (max.) : 1.08 m3
s/hr.
Supply pressure : 20.0 mbar
Burner pressure (max.) Hot : 14.3 mbar(*)
Burner pressure (max.) Cold : 12.8 mbar(**)
Burner pressure (min.) : 3.3 mbar(***)
Primary air inlet burner L : LR: Ø6.5 mm
Left-Rear and Left-Front LF: Ø4.5 mm
Primary air inlet burner M : MF: Ø7.0 mm
Middle-Front
Primary air inlet burner R : RR: Ø6.5 mm
Right-Rear and Right-Front RF: Ø4.5 mm
60


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires SMART BELL 75-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires SMART BELL 75-80 in the language / languages: English as an attachment in your email.

The manual is 2.5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires SMART BELL 75-80

Bellfires SMART BELL 75-80 User Manual - English - 36 pages

Bellfires SMART BELL 75-80 Installation Guide - German - 76 pages

Bellfires SMART BELL 75-80 User Manual - German - 36 pages

Bellfires SMART BELL 75-80 Installation Guide - Dutch - 68 pages

Bellfires SMART BELL 75-80 User Manual - Dutch - 36 pages

Bellfires SMART BELL 75-80 Installation Guide - French - 68 pages

Bellfires SMART BELL 75-80 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info