Bell res Deutsch
Installationsvorschrift
7.5 BELGIEN:
Nationale installations vorschriften : NBN D51 - 003 : Gas
AREI / RGIE : Elektrizität
Modell : DERBY LARGE 3 PF (PREMIUM FIRE)
DERBY SMALL 3 PF (PREMIUM FIRE)
TOPSHAM LARGE 3 PF (PREMIUM FIRE)
YORK LARGE 3 PF (PREMIUM FIRE)
YORK SMALL 3 PF (PREMIUM FIRE)
VIEW BELL DERBY 3 PF (PREMIUM FIRE)
VIEW BELL TOPSHAM 3 PF (PREMIUM FIRE)
CORNER BELL DERBY 3 L/R PF (PREMIUM FIRE)
CORNER BELL TOPSHAM 3 L/R PF (PREMIUM FIRE)
Gas : ERDGAS : BUTAN / PROPAN
Land : BE; Belgien : BE; Belgien
Produkt identifi kation nr. : 0063CM3684 : 0063CM3684
Geräte type laut CE-norm : C11 / C31 / C91 : C11 / C31 / C91
Geräte kategorie : I2E+ Erdgas G20/G25.3 : I3B/P Butan/Propan G30/G31
Nennwarme-belastung (Ho) : 12,1 kW : Butan (G30) : 11,2 kW
(Brennwert) Propan (G31) : 9,6
k
W
Nennleistung (max.) : 9,3 kW : 7,4 - 8,6 kW
Wirkungsgrad Klassifi kation : 1 (85%) : 1 (85%)
NOx-Klassifi kation : 5 : 5
Gasverbrauch (max.) : G20: 1,15 m3
s/hr. : Butan (G30) : 850 gr/hr.
G25.3: 1,18 m3
s/hr. Propan (G31) : 720 gr/hr.
Nennanschluß druck : G20: 20,0 mbar : Butan (G30) : 37,0 mbar
G25.3: 25,0 mbar Propan (G31) : 37,0 mbar
Düsendruck (max.) Warm : G20: 14,1 mbar(*) : 29,0 mbar(*)
G25.3: 17,6 mbar(*)
Düsendruck (max.) Kalt : G20: 13,4 mbar(**) : 29,0 mbar(**)
G25.3: 16,9 mbar(**)
Düsendruck (min.) : 2,5 mbar(***) : 7,0 mbar(***)
Primär belüftung Brenner L : LH : Ø6,0 mm : LH : Ø14 x 8 mm
Links-Hinten und Links-Vorn LV : Ø3,5 mm LV : Ø14 x 8 mm
Primär belüftung Brenner M : MV : Ø6,0 mm : MV : Ø15 x 8 mm +
Mitte-Vorn 2x Ø3,5 mm
Primär belüftung Brenner R : RH : Ø6,0 mm : RH : Ø14 x 8 mm
Rechts-Hinten und Rechts-Vorn RV : Ø3,5 mm RV : Ø14 x 8 mm
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires PREMIUM FIRE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires PREMIUM FIRE in the language / languages: German as an attachment in your email.

The manual is 3.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires PREMIUM FIRE

Bellfires PREMIUM FIRE Additional guide - English - 44 pages

Bellfires PREMIUM FIRE Additional guide - Dutch - 44 pages

Bellfires PREMIUM FIRE Additional guide - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info