1 INSTALLATION INSTRUCTIONS
1.1 GENERAL
The gas fi re must be positioned and connected as a “room sealed system” (balance
ue) appliance by a “Gas Safe Register” registered gas installation engineer in
accordance with the following installation instructions, nationally and locally applicable
regulations (see “Technical Details/ Regulations” at the rear of this manual). If you have
any queries regarding the installation, please consult your local gas company.
Important: Before beginning the installation, check that the details on the
rating plate correspond to the gas type and pressure to which
the appliance will be connected.
The appliance is supplied with a “Centre Fire” or “Line Fire” double burner, as ordered.
These burners each have their own specifi c fl ame image which is defi ned by the
perforation pattern in the burner cover. See Chapter 5 and the Instructions for use.
The appliance is factory set to the correct nominal heat input. The pilot light is set to the
correct level of consumption.
Depending on the requested version, the appliance will be delivered from the factory
with a Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm concentric connection for
extracting the fl ue gases and supply of combustion air.
It is possible to install the gas fi re with either a wall or roof outlet.
The roof connection must be carried out using the concentric fl ue system Ø100 mm -
Ø150 mm. The fumes are exhausted naturally to the outside environment through the
inner Ø100 mm pipe whereas the combustion air supply passes between the Ø100 mm
and Ø150 mm pipes.
The wall connection must be carried out using the concentric fl ue system Ø130 mm -
Ø200 mm. The fl ue gases are evacuated outside by means of natural draft through the
internal pipe of Ø130 mm, whereas the combustion air is supplied between the pipes of
Ø130 mm and Ø200 mm. The wall outlet itself is, depending on the concentric fl ue gas
system confi guration, Ø100 mm - Ø150 mm or Ø130 mm - Ø200 mm. (In some cases,
with a wall connection, a complete concentric fl ue system Ø100 mm - Ø150 mm is also
possible (see Chapter 1.6.1).)
The gas fi re can be installed in a completely sealed or mechanically ventilated house
without extra ventilation and/or fume extraction.
The gas fi re is installed as a built-in appliance in a fi re place.
In order to prevent the fi replace heating up excessively, it must be properly
ventilated by installing vents at the top and bottom of the fi replace.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires DERBY LARGE TUNNEL 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires DERBY LARGE TUNNEL 3 in the language / languages: English as an attachment in your email.

The manual is 2.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires DERBY LARGE TUNNEL 3

Bellfires DERBY LARGE TUNNEL 3 User Manual - English - 36 pages

Bellfires DERBY LARGE TUNNEL 3 Installation Guide - German - 108 pages

Bellfires DERBY LARGE TUNNEL 3 User Manual - German - 36 pages

Bellfires DERBY LARGE TUNNEL 3 Installation Guide - Dutch - 92 pages

Bellfires DERBY LARGE TUNNEL 3 User Manual - Dutch - 28 pages

Bellfires DERBY LARGE TUNNEL 3 Installation Guide - French - 92 pages

Bellfires DERBY LARGE TUNNEL 3 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info