571719
86
Zoom out
Zoom in
Previous page
1/96
Next page
86
Bell res Français
Notice d’installation
Modèle : CORNER BELL DERBY 3 G/D CF (Centre Fire)
Gaz : GAZ NATUREL : BUTANE / PROPANE
Pays : FR; France / BE; Belgique : FR; France / BE; Belgique
Veilleuse brûleur : SIT 0.145.019 : SIT 0.145.019
Injecteur veilleuse : no 36 (SIT 0.977.091) : no 23 (SIT 0.977.150)
Raccordement au gaz : 3/8” G / Ø12 mm : 3/8” G / Ø12 mm
Le raccordement systeme : Ø100 mm - Ø150 mm ou : Ø100 mm - Ø150 mm ou
concentrique Ø130 mm - Ø200 mm Ø130 mm - Ø200 mm
Piles télécommande
- Récepteur : 4x 1,5V AA : 4x 1,5V AA
- Émetteur manuel : 2x 1,5V AAA : 2x 1,5V AAA
Poids:
- Modèle de base: Hidden Door : 98 kg : 98 kg
- Modèle: Hidden Door avec 10 cm : 115 kg : 115 kg
cadre et support
- Option: kit de convection : 14 kg : 14 kg
(*) : Les deux brûleurs au maximum. L’appareil est à température.
(**) : Les deux brûleurs au maximum. L’appareil est froid.
(***) : Les deux brûleurs au minimum.
Évacuation des gaz de combustion et adduction d’air de combustion:
Sortie de toit : Systeme de canalisation concentrique Ø100 mm - Ø150 mm. Fixe et/ou ! exible.
Sortie murale : Systeme de canalisation concentrique Ø130 mm - Ø200 mm. Fixe. Avec sortie
murale, dépend de la situation de la canalisation; Ø100 mm - Ø150 mm ou
Ø130 mm - Ø200 mm.
Echangement de chaleur surface de travail: Toute la face avant de l’appareil.
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires CORNER BELL DERBY 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires CORNER BELL DERBY 3 in the language / languages: French as an attachment in your email.

The manual is 2.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires CORNER BELL DERBY 3

Bellfires CORNER BELL DERBY 3 Installation Guide - English - 96 pages

Bellfires CORNER BELL DERBY 3 User Manual - English - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - German - 112 pages

Bellfires CORNER BELL DERBY 3 User Manual - German - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - Dutch - 96 pages

Bellfires CORNER BELL DERBY 3 Usermanual and installation guide - Dutch - 28 pages

Bellfires CORNER BELL DERBY 3 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info