571719
54
Zoom out
Zoom in
Previous page
1/96
Next page
54
Bell res English
Installation instructions
Gas pipe
“rear burner”
Ø8 mm Flex.
Gas valve
“rear burner”
Gas pipe
“front burner”
Ø8 mm Flex.
Gas supply
connection
Gas regulator block
Thermocouple
Pilot light pipe
Ø4 mm Flex.
Thermocouple
interrupter
Figure 19: Gas regulator block and gas valve: Gas and thermocouple connections
Important : Cement and chalk can damage
the piping and can, in turn,
lead to gas leaks.
Disassembly and assembly of pipes and cables:
If necessary for mounting, all pipe compression fi ttings and cable connectors can be
temporarily disassembled. After mounting, carefully reassemble all pipes and cables.
Check afterwards all compression fi ttings for leaks and that all electric connections are
properly connected.
Important : Screw the thermocouple connection (and thermocouple
interrupter) manually into the gas regulator block. Afterwards,
carefully fasten a half turn with a spanner.
Note : Check that the fl exible burner pipes are correctly connected!
The gas connection of the gas valve “rear burner” must be
connected to the “rear burner”! See Chapter 5. Switching over the
exible burner pipes during assembly can lead to an explosive
ignition. Prevent this at all costs!
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires CORNER BELL DERBY 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires CORNER BELL DERBY 3 in the language / languages: English as an attachment in your email.

The manual is 2.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires CORNER BELL DERBY 3

Bellfires CORNER BELL DERBY 3 User Manual - English - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - German - 112 pages

Bellfires CORNER BELL DERBY 3 User Manual - German - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - Dutch - 96 pages

Bellfires CORNER BELL DERBY 3 Usermanual and installation guide - Dutch - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - French - 96 pages

Bellfires CORNER BELL DERBY 3 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info