571719
94
Zoom out
Zoom in
Previous page
1/112
Next page
94
Bell res Deutsch
Installationsvorschrift
7.3 TECHNISCHE DATEN; N-LU; ERDGAS - LUXEMBURG
P-LU; PROPAN - LUXEMBURG
Nationale Installationsvorschriften:
A - No 104 Installations de combustion alimentees en gaz
Modell : CORNER BELL DERBY 3 L/R CF (Centre Fire)
Gas : ERDGAS : BUTAN / PROPAN
Land : LU; Luxemburg : LU; Luxemburg
Produkt identifi kation nr. : 0063CM3684 : 0063CM3684
Geräte type laut CE-norm : C11 / C31 / C31S : C11 / C31 / C31S
Geräte kategorie : I2E Erdgas G20 : I3B/P Butan/Propan G30/G31
Nennwarme-belastung : 11,5 kW : Butan (G30) : 10,0 kW
(Ho) Propan (G31) : 8,5 kW
Nennleistung (max.) : 8,8 kW : 6,6 - 7,7 kW
Wirkungsgrad Klassifi kation : 1 (85%) : 1 (85%)
NOx-Klassifi kation : 5 : 5
Gasverbrauch (max.) : G20:
1,10 m3
s/hr. : Butan (G30) : 780 gr/hr.
Propan (G31) : 640 gr/hr.
Nennanschluß druck : 20,0 mbar : Butan (G30) : 50,0 mbar
Propan (G31) : 50,0 mbar
Düsendruck (max.) Warm : 13,0 mbar(*) : 29,0 mbar(*)
Düsendruck (max.) Kalt : 12,3 mbar(**) : 29,0 mbar(**)
Düsendruck (min.) : 0,5 mbar(***) : 2,0 mbar(***)
Primär belüftung Brenner : 1x Ø10,0 mm : 1x Ø20,0+ Ecke mm +
Rückseite 2x Ø5,0 mm
Primär belüftung Brenner : 1x Ø10,0 mm : 1x Ø20,0+ Ecke mm +
Vorderseite 2x Ø5,0 mm
Gasregelblock (Fernbedienung) : Mertik GV 60 : Mertik GV 60
Hauptbrenner : Centre Fire 561 x 130 mm : Centre Fire 561 x 130 mm
Primär belüftung Brenner Rückseite : nr. 200 (= 1x Ø2,00 mm) : nr. 95 (= 1x Ø0,95 mm)
Primär belüftung Brenner Vorderseite : nr. 200 (= 1x Ø2,00 mm) : nr. 125 (= 1x Ø1,25 mm)
94


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires CORNER BELL DERBY 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires CORNER BELL DERBY 3 in the language / languages: German as an attachment in your email.

The manual is 2.72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires CORNER BELL DERBY 3

Bellfires CORNER BELL DERBY 3 Installation Guide - English - 96 pages

Bellfires CORNER BELL DERBY 3 User Manual - English - 28 pages

Bellfires CORNER BELL DERBY 3 User Manual - German - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - Dutch - 96 pages

Bellfires CORNER BELL DERBY 3 Usermanual and installation guide - Dutch - 28 pages

Bellfires CORNER BELL DERBY 3 Installation Guide - French - 96 pages

Bellfires CORNER BELL DERBY 3 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info