812694
7
Zoom out
Zoom in
Previous page
1/52
Next page
4
4Requirements
4.1 Requirements on the location
The floor must be sufficiently strong and stable, because of the weight of the
appliance.
Make sure that you keep the minimum safety distances of the appliance to flammable
and nonflammable materials. Refer to the installation and maintenance manual.
Make sure the wall can support the weight of an appliance when attached to the wall.
Situate the appliance in such a way that the concentric flue outlet connection is
precisely in line with the concentric flue pipe to the ceiling or wall.
If the fire burns in the appliance, make sure that the wall temperatures, and floor
temperatures below and in front of the appliance, cannot be higher than 85 °C .
Make sure that the room where the appliance is installed is properly ventilated.
4.2 Other requirements
The gas supply connection is located at the rear of the appliance for an easy
connection to all directions.
Only use gas piping of at least 1/2" and a shut-off valve to connect the gas supply to
the gas connection of the appliance.
Make sure that there is a wall socket with earth connection nearby the appliance. The
socket must be accessible at all times. The powercable (+ 0.5 m) is coming from the
rear of the appliance.
If the wall of floor is made of flammable material, take correct safety measures. Refer
to the installation and maintenance manual.
If the concentric flue system is installed in a chimney that is used for wood or coal fire,
clean the chimney.
4.3 Requirements on the outlet
4.3.1 Requirements on the roof outlet
Make sure that the outlet is installed at least 0.5 meter from the edge of the roof.
Note:
All the minimum distances are guidelines. Consult your national and local
directives for the exact minimum distances.
Location of any of the items(*) Minimum distance between the items
and the roof outlet
At the same roof as the outlet 3 m
At a different roof as the outlet 1 m
At a lower positioned wall than the outlet 1 m
At a higher sloping surface than the outlet 3 m
(*) Items:
A ventilation opening that services an occupied room, a toilet or a bathroom.
A combustibion air supply, if the supply flows through an occupied room.
A window that can be opened that services an occupied room, a toilet or a bathroom.
Requirements
Box Gas Panorama 45/59
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bellfires Box Gas Panorama 45-59 MF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bellfires Box Gas Panorama 45-59 MF in the language / languages: English as an attachment in your email.

The manual is 2.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bellfires Box Gas Panorama 45-59 MF

Bellfires Box Gas Panorama 45-59 MF Installation Guide - English - 48 pages

Bellfires Box Gas Panorama 45-59 MF User Manual - English - 32 pages

Bellfires Box Gas Panorama 45-59 MF Additional guide - German - 56 pages

Bellfires Box Gas Panorama 45-59 MF Installation Guide - German - 52 pages

Bellfires Box Gas Panorama 45-59 MF User Manual - German - 32 pages

Bellfires Box Gas Panorama 45-59 MF Additional guide - Dutch - 56 pages

Bellfires Box Gas Panorama 45-59 MF Installation Guide - Dutch - 52 pages

Bellfires Box Gas Panorama 45-59 MF User Manual - Dutch - 32 pages

Bellfires Box Gas Panorama 45-59 MF Additional guide - French - 56 pages

Bellfires Box Gas Panorama 45-59 MF Installation Guide - French - 48 pages

Bellfires Box Gas Panorama 45-59 MF User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info