Local air-conditioner / User Manual
Ensure that the outlet for the vacuum pump s
not close to any gnton sources and there s
ventlaton avalable.
2.8 Chargng procedures
In addton to conventonal chargng
procedures,the followng requrements shall be
followed.
Ensure that contamnaton of dfferent
refrgerants does not occur when usng
chargng equpment. Hoses or lnes shall
be as short as possble to mnmze the
amount of refrgerant contaned n them.
Cylnders shall be kept uprght.
Ensure that the refrgeraton system s
earthed pror to chargng the system wth
refrgerant.
Label the system when chargng s
complete (f not already).
Extreme care shall be taken not to overfll
the refrgeraton system.
Pror to rechargng the system t shall be
pressure tested wth OFN. The system shall be
leak tested on completon of chargng but pror
to commssonng. A follow up leak test shall be
carred out pror to leavng the ste.
2.9 Decommssonng
Before carryng out ths procedure, t s essental
that the techncan s completely famlar wth the
equpment and all ts detal. It s recommended
good practce that all refrgerants are recovered
safely. Pror to the task beng carred out, an ol
and refrgerant sample shall be taken n case
analyss s requred pror to re-use of reclamed
refrgerant. It s essental that electrcal power s
avalable before the task s commenced.
a) Become famlar wth the equpment and
ts operaton.
b) Isolate system electrcally.
c) Before attemptng the procedure ensure
that: mechancal handlng equpment
s avalable, f requred, for handlng
refrgerant cylnders; all personal
protectve equpment s avalable and
beng used correctly; the recovery process
s supervsed at all tmes by a competent
person; recovery equpment and cylnders
conform to the approprate standards.
d) Pump down refrgerant system f possble.
e) If a vacuum s not possble, make a manfold
so that refrgerant can be removed from
varous parts of the system.
f) Make sure that cylnder s stuated on the
scales before recovery takes place.
g) Start the recovery machne and operate
n accordance wth manufacturer’s
nstructons.
h) Do not overfll cylnders. (No more than 80 %
volume lqud charge).
) Do not exceed the maxmum workng
pressure of the cylnder,even temporarly.
j) When the cylnders have been flled
correctly and the process completed, make
sure that the cylnders and the equpment
are removed from ste promptly and all
solaton valves on the equpment are
closed off.
k) Recovered refrgerant shall not be charged
nto another refrgeraton system unless t
has been cleaned and checked.
2.10 Labellng
2. Instructons for reparng applances contanng
R290
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BEKO BP207C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BEKO BP207C in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 11,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info