18 / 276 EN Local ar condtoner / Instructon Manual
be calbrated to the refrgerant employed and the approprate
percentage of gas (25 % maxmum) s confrmed. Leak detecton
fluds are sutable for use wth most refrgerants but the use of
detergents contanng chlorne shall be avoded as the chlorne may
react wth the refrgerant and corrode the copper ppe-work. If a
leak s suspected, all naked flames shall be removed/ extngushed.
If a leakage of refrgerant s found whch requres brazng, all of
the refrgerant shall be recovered from the system, or solated
(by means of shut off valves) n a part of the system remote from
the leak. Oxygen free ntrogen (OFN) shall then be purged through
the system both before and durng the brazng process.
12. Removal and evacuaton
When breakng nto the refrgerant crcut to make repars or for any
other purpose conventonal procedures shall be used. However,
t s mportant that best practce s followed snce flammablty s
a consderaton. The followng procedure shall be adhered to:
Remove refrgerant;
Purge the crcut wth nert gas;
Evacuate;
Purge agan wth nert gas;
Open the crcut by cuttng or brazng.
The refrgerant charge shall be recovered nto the correct recovery
cylnders. The system shall be flushed wth OFN to render the
unt safe. Ths process may need to be repeated several tmes.
Compressed ar or oxygen shall not be used for ths task.
2 Warnngs (for usng R290 refrgerant only)
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BEKO BA312C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BEKO BA312C in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 24.26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info