PHONES/CTRL R(oom)
Use this control to set control room output level and head-phones
volumerespectively.
CD/TAPE TO MAIN
When the CD/TAPE TO MAIN switch is depressed, the 2-track input is routed to
the main mix and thus serves as an additional input for tape machines. You can
also connect MIDI instruments or other signal sources here that do not require
any further processing. At the same time, this switch disables the main mix to
tape output link.
POWER
The blue POWER LED indicates that the device is switched on.
+48 V
The red “+48 V” LED lights up when the phantom power supply is switched
on. The phantom power supply is necessary for condenser microphones and is
activated using the switch on the rear of the device.
Please do not connect microphones to the mixer (or the stagebox/
wallbox) while the phantom power supply is switched on.
Connect micro-phones before you switch on the power supply.
In addition, the monitor/PA loudspeakers should be muted before you
activate the phantom power supply. After switching on, wait approx.
one minute to allow for system stabilization.
LEVEL METER
The high-precision level meter accurately displays the appropriate signal level.
LEVEL SETTING:
When recording to a digital device, the recorder’s peak meter should not exceed
0 dB. This is because, unlike analog recordings, slightly excessive levels can create
unpleasant digital distortion.
When recording to an analog device, the VU meters of the recording machine
should reach approx. +3 dB with low-frequency signals (e.g. kick drum). Due to
their inertia VU meters tend to display too low a signal level at frequencies above
1 kHz. This is why, for example, a Hi-Hat should only be driven as far as -10 dB.
Snare drums should be driven to approx. 0 dB.
The peak meters of your XENYX display the level virtually independent
of frequency. A recording level of 0 dB is recommended for all
signaltypes.
MODE (1204FX only)
The MODE switch determines whether the channels’ SOLO switch operates as PFL
(Pre Fader Listen) or as solo (Solo In Place).
PFL
To activate the PFL function, depress the MODE switch. The PFL function should,
as a rule, be used for gain setting purposes. The signal is sourced pre-fader and
assigned to the mono PFL bus. In the “PFL” setting, only the left side of the peak
meter operates. Drive the individual channels to the 0 dB mark of the VU meter.
Solo
When the MODE switch is not depressed, the stereo solo bus is active. Solois
short for “Solo In Place. This is the customary method for listening to an
individual signal or to a group of signals. As soon as a solo switch is pressed,
allchannels in the control room (and headphones) that have not been selected
are muted thereby retaining stereo panning. The solo bus can carry the output
signals of the channel pan controls, the aux sends and the stereo line inputs.
Thesolo bus is, as a rule, switched post-fader.
The PAN control in the channel strip offers a constant power
characteristic. This means that the signal is always at a constant level,
irrespective of its position in the stereo panorama. If the PAN control
is moved fully left or right from center, the level increases by 4 dB
in that channel. This ensures that, when set in the center, the audio
signal is not louder. For this reason, with the solo function activated
(Solo in Place), audio signals from the channels with PAN controls that
have not been moved fully to the left or right are displayed at a lower
volume than in the PFL function.
As a rule, solo signals are monitored via the control room outputs and
headphones connector and are displayed by the level meters. If a solo switch is
pressed, the signals from the tape input, Alt 3-4 and main mix are blocked from
the control room outputs, the headphone connector and the level meter.
MAIN SOLO (1204FX only)
The MAIN SOLO LED lights up as soon as a channel or aux send solo switch is
pressed. The MODE switch also has to be set at “Solo”.
PFL (1204FX only)
The PFL LED indicates that the peak meter is set to PFL mode.
Fig. 2.12: PHONES connector
PHONES
You can connect headphones to this ¼" TRS connector. The signal on the PHONES
connection is sourced from the control room output.
2.3.7 Alt 3-4 and main mix fader
Fig. 2.13: Alt 3-4 and main mix fader
Use the high-precision quality faders to control the output level of the Alt 3-4
subgroup and main mix.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Behringer Xenyx X1204USB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Behringer Xenyx X1204USB in the language / languages: English as an attachment in your email.

The manual is 3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Behringer Xenyx X1204USB

Behringer Xenyx X1204USB User Manual - English - 14 pages

Behringer Xenyx X1204USB Quick start guide - German, Dutch, Danish - 26 pages

Behringer Xenyx X1204USB User Manual - French - 14 pages

Behringer Xenyx X1204USB Quick start guide - Italian, Polish, Portuguese, Swedish - 26 pages

Behringer Xenyx X1204USB User Manual - Spanish - 14 pages

Behringer Xenyx X1204USB Quick start guide - Norwegian - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info