8 XENYX 1202/1002/802/502 User Manual
2-TRACK OUTPUT
These connectors are wired in parallel with the MAIN OUT and carry the main
mix signal (unbalanced). Connect the 2-TRACK OUTPUT to the inputs of your
recording device. The output level is adjusted via the high-precision MAIN MIX
fader or rotary control (802).
2.3.4 Signal assignment
Fig. 2.12: Assignment switches of the main section
2-TR TO MIX
When the 2-TR TO MIX switch is depressed, the2-track input is assigned to the
main mix providing an additional input for tape machines, MIDI instruments or
other signal sources that do not require any processing.
2-TR TO CTRL ROOM (502: 2-TR TO PHONES)
Press the 2-TR TO CTRL ROOM/PHONES switch if you want to monitor the
2-track input via the CTRL ROOM OUT. This provides an easy way to monitor
signals coming back from tape to ensure that they are recording correctly.
◊ If you are recording a signal via the 2-TRACK OUTPUT and wish to listen
to this simultaneously via the 2-TRACK INPUT, do not use the 2-TR TO
MIX switch. Doing this would create a feedback loop, since the signal
would be routed, via the main mix, back to tape via the 2-TRACK
OUTPUT. To monitor the 2-TRACK INPUT, use the 2-TR TO CTRL ROOM
switch to assign the tape signal to the monitor(s) or headphones.
This will avoid the tape signal being routed to the 2-TRACK OUTPUT.
FX TO CTRL
If you want to monitor only the FX send signal in your headphones or monitor
speaker(s), press the FX TO CTRL switch. This mutes the main mix signal while
routing the FX SEND output to the monitor(s). The XENYX 802 and 502 do not
feature this switch.
2.3.5 Phantom power and LED displays
Fig. 2.13: Phantom power and control LEDs
+48 V
The red +48 V LED lights up when phantom power is on. The PHANTOM switch
activates the phantom power supply on the XLR connectors of all mono channels.
◊ Please do not connect microphones to the mixer (or the stagebox/
wallbox) as long as the phantom power supply is switched on.
Connect the micro-phones before you switch on the power supply.
In addition, the monitor/PA loudspeakers should be muted before you
activate the phantom power supply. After switching on, wait approx.
one minute in order to allow system stabilization.
POWER
The blue POWER LED indicates that the console is powered on.
Level indicator
The high-precision 4-segment display accurately displays the relevant
signallevel.
LEVEL SETTING: To correctly set the gains of the channels, rst set the LEVEL
controls of the input channels to their center positions (0 dB). Then use the GAIN
controls to increase the input amplication until signal peaks show 0 dB on the
level meter.
When recording to digital recorders, the recorders peak meter should not go into
overload. While analog recorders can be overloaded to some extent, creatingonly
a certain amount of distortion (which is common and often desirable),
digitalrecorders distort quickly when overloaded. In addition, digital distortion is
not only undesirable, but also renders your recording completely useless.
◊ The peak meters of your XENYX display the level virtually independent
of frequency. A recording level of 0 dB is recommended for all
signal types.
3. Installation
3.1 Mains connection
AC POWER IN
Connect the power supply to the 3-pin mains connector on the rear of the
console. Use the AC adapter supplied to connect the console to the mains.
Theadapter complies with all applicable safety standards.
◊ Please use only the power supply unit provided with the console.
◊ Never connect the XENYX to the power supply unit while the latter is
connected to the mains! First connect the console to the power supply
unit, then connect the power supply unit to the mains.
◊ Please note that both the power supply unit and the mixing console
heat up considerably during operation. This is completely normal.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Behringer Xenyx 502 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Behringer Xenyx 502 in the language / languages: English as an attachment in your email.

The manual is 2,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Behringer Xenyx 502

Behringer Xenyx 502 User Manual - German - 12 pages

Behringer Xenyx 502 User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info