23 X AIR User Manual
other microphones. In each channel's Main tab, a Weight knob is included which
allows certain channels to be attenuated more or less to compensate for louder
voices or more sensitive microphones.
6.9 Meters
The Meters tab allows easy monitoring of all analog and digital levels, including
USB channels, Buses, Ultranet outputs, and the Main and Solo buses.
6.10 Eect Rack
The Eect Rack page is accessed via the “FX” icon at the top of the Main View
screen. There are 4 slots where various eects can be selected and adjusted
to suit the application. Tap on the eect slot to select an eect and adjust the
available parameters.
6.11 Snapshots
The snapshot function allows specic bits of information to be saved for
immediate recall. For example, quick changes can be selected for dierent acts
of a play, performances in a music festival with several bands, or dierent
church services.
Click the camera icon at the top of the main screen. A window will open with a list
of parameters to select for recall. You can select individual channels/parameters
that will be recalled from a previously saved snapshot, or click the ‘All’ button to
choose everything in a category. There may be channels, buses, parameters, etc.
that should remain unaected throughout an event, so this method is benecial
for its highly specic method of recall.
To save a snapshot, press and hold one of the slots in the left-hand list. A new
entry will appear in the list where you can type in a name for the new snapshot.
To recall a previously-saved snapshot, press and hold the item in the list and then
select the Load option. Note that all aspects of the current arrangement will be
saved to a new snapshot slot, and the specic elements of that snapshot can be
selected upon recall.
The snapshot recall parameters are listed in 3 categories: channel, parameter
and global.
The Channel Section lets you determine which channels or bus masters will be
aected during recall.
The Parameter Section lets you determine which specic preamp elements will
be recalled for the channels and buses selected in the Channel Section above.
Source aects the input vs. USB selection, Input recalls basic preamp settings
such as phantom and gain setting, and Cong recalls the conguration. EQ, Dyn,
Fdr/Pan and Mute recall these settings for the selected channels, and the bus/FX
sends can be individually assigned for recall.
Global Settings allow the input/output routing to be recalled, as well as global
conguration, DCA assignments, and FX block settings.
To delete a snapshot that is no longer necessary, select it from the list and then
select Delete.
6.12 Scenes and Shows
The Scenes/Shows page is accessed via the folder icon at the top of the
MainViewscreen. This page allows you to save, edit and recall specic scenes or
entire shows. To prevent certain channels or buses from being aected by scene
or show recalls, arm the desired sources in the ’Channel safes’ section.
6.13 Routing
The Routing menu is accessed via the up/down arrow icon at the top of the
MainView screen. This allows the specic routing of input, output, USB and
monitor buses to be adjusted freely.
Tap inside an empty box in the grid to move the orange dots and reassign
the source for input channels, USB channels and P16 monitoring sources.
Modications to the Inputs/USB routing can be reset by pressing the revert
button on the far right. The USB sends and inputs can be selected from a menu in
the folder icon, or they can be moved manually.
The Routing – Outputs page allows the Main LR, Phones, Aux and P16 sources to
be reassigned.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Behringer XAir - XR16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Behringer XAir - XR16 in the language / languages: English as an attachment in your email.

The manual is 14,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Behringer XAir - XR16

Behringer XAir - XR16 Quick start guide - English, German, French, Portuguese, Spanish - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info