54 X32 COMPACT DIGITAL MIXER User Manual
6. Adjust the 3rd encoder to set the word clock synchronization of the
console to use its internal digital clock, or slave to an external digital clock.
Choicesfor the clock signal include:
• Internal clock
• External clock from the AES50-A port
• External clock from the AES50-B port
• X-USB card
Note that the graphics at the top of the screen will always display a green led
when the console has achieved proper “digital lock”, from either its own internal
clock or a valid external clock.
7. Tap the 4th encoder to cycle through the dierent settings for the consoles
internal date and time settings.
8. Adjust the 4th encoder to set the value for the currently selected
date/timesetting.
9. Adjust the 5th encoder to select the console’s “Bus Pre-Conguration”.
Thissettings allows the mix bus outputs to be congured in various
combinations of:
• Pre-fader, variable output auxiliary sends
• Post-Fader, variable output auxiliary sends
• Fixed-output sub groups
10. Choices include:
• 8 pre-fader auxiliary sends, 8 post-fader auxiliary sends,
and no sub-groups
• 8 pre-fader auxiliary sends, 4 post-fader auxiliary sends,
and 4 sub-groups
• 6 pre-fader auxiliary sends, 4 post-fader auxiliary sends,
and 6 sub-groups
• 4 pre-fader auxiliary sends, 4 post-fader auxiliary sends,
and 8 sub-groups
• 10 pre-fader auxiliary sends, 6 post-fader auxiliary sends,
and 0 sub-groups
11. Tap the 5th encoder to assign the currently selected conguration.
As the conguration is selected, a display on the right-hand side of the color
screen changes to show the currently selected conguration.
7.5.3 Setup Screen: Remote Tab:
The setup screen’s remote tab allows setting up the console as a control surface
for various DAW recording software on a connected computer. With its large
complement of motorized faders, the console can act as an excellent controller
for various DAW software, allowing the user to make level adjustments quickly
and easily without using a mouse.
To adjust the various remote settings, perform the following steps:
1. Tap the 1st encoder to enable the console’s top panel Remote button.
Thisswitches various console hardware, such as the bus faders, tocontrol
computer DAW software instead of the console’s internal audiopath.
2. Adjust the 2nd encoder to select the specic control surface protocol used,
inconjunction with the target DAW software. Choices include:
• Mackie Control: Use this protocol to control any DAW software that is
compatible with a Mackie Control hardware control surface.
• HUI: Use this protocol to control any D.A.W. software that is compatible
with a HUI hardware control surface, such as Pro Tools.
3. Tap the 2nd encoder to assign the currently selected control surface protocol.
4. Adjust the 5th encoder to select whether the remote function uses the MIDI
In and OUT jacks or the X-USB card’s MIDI.
5. Tap the 5th encoder to conrm the selection.
6. Adjust the 6th encoder to adjust various MIDI-based operations for the
console. Choices include:
• MIDI In/Out: This toggles the MIDI input and outputs for the console
on/o.
• Card MIDI: Allows MIDI transmission through the X-USB card.
• USB In/Out: This toggles the console’s USB ports on/o.
• RTP (Real-time Transport Protocol): This toggles on/o the console’s
ability to interface with an Ethernet-based MIDI system.
• Enable MIDI scene recall: This toggles on/o the console’s response to
incoming MIDI messages for switching console scenes.
7. Tap the 6th encoder to toggle the currently selected MIDI option
on/o. Thiscan be useful if you want to ensure that any connected MIDI
transmitters cannot interfere with the console.
7.5.4 Setup Screen: Network Tab:
The setup screen’s network tab contains settings used when connecting the
console to a standard Ethernet network. The user can set parameters such as
using a xed IP address or having one assigned, as well as setting up the Ethernet
and subnet mask settings.
To set the network address for the console, perform the following steps:
1. Adjust the 1st encoder to select which specic network eld to adjust.
Choices include:
• IP Address
• Subnet Mask
• Gateway
2. Adjust encoders 2, 3, 4, and 5 to set the 4 numerical elds to be adjusted,
forthe selected network eld.
3. Tap the 6th encoder to assign the adjusted settings.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Behringer X32 Compact at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Behringer X32 Compact in the language / languages: English as an attachment in your email.

The manual is 15,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Behringer X32 Compact

Behringer X32 Compact Quick start guide - English, German, French, Portuguese, Spanish - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info