HOLD / ZERO
Press HOLD to freeze the display reading (
is
displayed) and releases the reading when pressed a
second time.
W
Warning
To avoid possible electric shock or personal injury,
when Display HOLD is activated, be aware that the
display will not change when you apply a different
voltage.
Press
ZERO (HOLD) > one second to clear last
reading from the display (
is displayed) and establish
a baseline for applicable selected functions.
DC-Zero mode for dc and ac+dc currents. Press
ZERO
(HOLD) > one second to activate DC-Zero (display
shows “dc_0” for one second). When nulled value is
larger than ± 5 DC A, an acoustic warning (3 short
beeps) will occur.
REC / PEAK-RMS Press REC button to activate maximum, minimum and
average reading memory mode (
MAX MIN AVG
is displayed). The meter beeps when MAX and MIN
reading is updated during measurement. Press REC
button again to read the MAX, MIN and AVG reading
in sequence. Press REC button > one second to exit
MAX/MIN/AVG reading memory mode.
Press REC / PEAK-RMS button > one second to enter
PEAK-RMS mode (
is displayed) to capture
inrush current or voltage RMS values (80 ms). Press a
second time > one second to exit.
Note: Auto Power Off is automatically disabled under
MAX/MIN/AVG and PEAKRMS modes.
Measuring AC and DC Voltage
To measure ac or dc voltage:
1. Turn the rotary function switch to
or
2. Press SELECT button to choose measurement function: AC V, DC V,
DC+AC V, Hz or EF(Non contact voltage detection). The display reflects
the chosen function mode. For Model AMP-210 and AMP-220, NCV(EF)
function is designed in an independent rotary switch position. See the
Non-Contact Voltage Detection chapter for details.
3. Connect the black test lead to the COM terminal and the red test lead
to the V terminal. Before connecting the probes to the measurement
points, add any clips to the probes that are necessary.
4. Measure the voltage by touching the probes to the desired test points
of the circuit.
5. View the reading on the display.
6. When measuring AC voltage, press SELECT button to view the
frequency reading on the display.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beha-Amprobe AMP-320 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beha-Amprobe AMP-320 in the language / languages: English as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info