15
Normal mode
for the MAINS circuit:
Connect the test lead L1/L2/L3 to the 3-phase mains circuit by using probes
and/or alligator clips. If the meter indicates a clockwise movement, the
phases connected to L1, L2 and L3 of the meter are L1, L2 and L3 (also
known as R, S and T), respectively. If the meter indicates a counter-clockwise
movement, swap any two connects between the meter and phases. Then
retest. Connecting the above mentioned L1, L2 and L3 of a motor and that
of the MAINS respectively should get a clockwise motor movement.
Using the Beeper feature on
& mode:
Press and hold the REC button while turning the rotary switch to
to enable the beeper, the display shows “Enbp”. When making rotary
measurement, if the rotary indication segments indicate a clockwise
movement, the beeper sounds a single long beep per segment cycle. If the
rotary indication segments indicate a counter clockwise movement, the
beeper sounds 3 short beeps per segment cycle.
Auto Power Off
The meter turns off if there is no button pushed, rotary function switch
operation for 32 minutes and/or no specified activities below, where
applicable:
1.) Significant measuring readings of above 8.5% of ranges
2.) Non-OL readings for Resistance, Continuity or Diode function
3.) Non-zero readings for Hz function
4.) Significant movement indication as in Phase Rotation functions
The meter will not enter auto power off mode when under normal
measurements. To turn the meter back on, press the SELECT button and
release, or turn the rotary switch off and on to restart the meter.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beha-Amprobe AMP-310 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beha-Amprobe AMP-310 in the language / languages: English as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info