11INSTALLATION WARNINGS
INSTALLATION WARNINGS
WARNING
WARNING
This appliance shall only be used in an above ground,
open air situation with natural ventilation without
stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind or natural
convection. This barbecue has been designed for
outdoor use only. Failure to adhere to these installation
instructions may cause injury or property damage
and affect your ability to make a claim under the
manufacturer’s warranty. Refer to diagrams below.
Never install this barbecue inside any building,
garage, shed or breezeway or inside a boat, caravan or
recreational vehicle. This is to prevent the possibility of
fire or carbon monoxide poisoning or asphyxiation.
Any enclosure in which this appliance is installed shall
comply with one of the following:
An enclosure with walls on all sides, but at least
one permanent opening at the ground level and no
overhead covering
Within a partial enclosure that includes an overhead
cover and no more than 2 walls
Within a partial enclosure that includes an overhead
cover and more than 2 walls, the following shall apply:
At least 25% of the total wall area is completely open
and at least 30% of the remaining wall area is open
and unrestricted
In the case of balconies, at least 20% of the total of the
side, back and front wall areas shall be and remain open
and unrestricted.
Outdoor area
example 1
Outdoor area
example 2
Outdoor area
example 3
both ends
open
open side at
least 25% of
total wall area
open side at
least 25% of
total wall area
Outdoor area
example 4
Outdoor area
example 5
30% or more
in total of the
remaining wall
area is open and
unrestricted
30% or more
in total of the
remaining wall
area is open and
unrestricted
Choosing a location
When planning the location and preparing the installation
structure for this appliance note the following:
This appliance must be installed in accordance with with
local authority and any relevant statutory regulations.
Requirements in these instructions for clearances
to combustible materials also apply to combustible
materials that have non-combustible materials attached
to their surface.
The minimum clearance from combustible construction
materials to all sides of the appliance is 450mm.
The minimum clearance to a vertical wall above bench
level that is made from combustible material is 450mm.
The vertical clearance above the cooking surface to any
combustible materials must be at least 1000mm.
When using LPG in an enclosure ventilation must be
provided. Gas is highly explosive and can cause serious
injury and damage to property if allowed to accumulate
and then be ignited.
Avoid windy positions as this will affect cooking
performance and burner efficiency. If this situation
cannot be avoided some shielding may be necessary.
Natural gas requirements
The enclosure must be constructed so that access can
be gained to the natural gas regulator at all times.
Natural gas conversions
WARNING
WARNING
Conversion of this unit to natural gas must be carried out by
a qualified licensed person and a Certificate of Compliance
must be issued to the owner on completion of the installation
and conversion. Conversion of this barbecue by unlicensed
persons may result in improper functioning of the appliance,
injury, property damage and may affect your ability to make a
claim under the manufacturer’s warranty.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beefeater 1500 series - Built-in at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beefeater 1500 series - Built-in in the language / languages: English as an attachment in your email.

The manual is 3.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beefeater 1500 series - Built-in

Beefeater 1500 series - Built-in User Manual - English - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info