665847
8
Zoom out
Zoom in
Previous page
1/14
Next page
14 15
PARAMETER SETTING
1 Items to be Set:
1 Data reset
2 km/mile
3 Light sensitivity
4 Display backlight brightness
5 Automatic o time
6 Maintenance warning settings
7 Input of the password
8 Wheel diameter selection
9 Setting speed limit
2 Setting Preparation
When the display is active, press i twice (interval
< 0.3 seconds). The system will enter the MENU
parameter setting state, in which the display pa-
rameters can be set. Press i twice again (interval
< 0.3 seconds) to return to the main menu.
In the parameter setting state, when the
parameter you want to set begins to flash, press
/ to adjust the parameter value. Briefly press
to switch between the parameters to be set.
Press twice (interval < 0.3 seconds) to exit the
submenu. If no operation is performed for 10
seconds, the display will return to the normal
riding display.
3 Data Reset
Press i twice (interval < 0.3 seconds) – the dis-
play enters the MENU state. In the speed field tC
is displayed. If you press + , a y is also displayed.
Now all temporary data, e.g. maximum speed
(MAXS), average speed (AVG) and single-trip dis-
tance (TRIP) can be cleared. Briefly press (< 0.3
seconds) to enter the km/mile setting interface.
If the user does not reset the data, the single
trip distance and the accumulated total riding
time will be automatically cleared when the
accumulated total riding time exceeds 99 hours
and 59 minutes.
Note: The data will not be cleared when the
display’s lightsensing
function is set to 0 or when it is switched o.
4 km/mile
When the speed field displays S7, press +/- to
switch between km/h and mph, or to set km
or mile.
Aer this setting, briefly press i (< 0.3 seconds) to
enter the setting interface of light sensitivity.
5 Light Sensitivity
When the speed field displays bL0, use +/- to
choose a figure between 0 and 5. The higher the
chosen figure, the higher the light sensitivity.
Aer this setting, briefly press i (< 0.3 seconds)
to enter the setting interface of backlight
brightness.
6 Display Backlight Brightness
When the speed field displays bL1, press +/- to
choose a figure between 1 and 5. The figure 1 re-
presents the lowest brightness while 5 indicates
the highest display backlight brightness.
Aer this setting, briefly press i (< 0.3 seconds) to
enter the setting interface of automatic o time.
7 Automatic O Time
When the speed field displays OFF, press+/- to
choose a figure between 1 and 9. The figures in-
dicate the minutes that it takes to automatically
shut down the display.
Aer this setting, briefly press i (< 0.3 seconds)
to enter the setting interface of maintenance
warning.
8 Maintenance Warning (can be deactivated)
When the speed field displays nnA, press +/- to
choose either 0 or 1. 0 disables the function
while 1 enables it.
Aer this setting, briefly press (< 0.3 seconds) to
enter the setting interface of password input.
The display will prompt maintenance necessity
based on such information as the accumulated
riding distance and the battery charge cycles.
• When the accumulated total riding distance
exceeds 5,000 km (can be customized by the
manufacturer), the display will show the symbol
. When SERVICE the display is started up, the
sign for accumulated riding distance will flash
for 4 seconds, indicating that maintenance is
necessary.
• When the number of battery charge cycles
exceeds 100 (can be customized by the manu-
facturer), the display will the symbol SERVICE.
When the display is started up, the sign for
battery will flash for 4 seconds, indicating that
maintenance is necessary.
• The maintenance alert function can be
disabled: settings / maintenance alert (MA) /
maintenance alert (MA) / 0. (Maintenance alert
can also be set via a computer. This requires a
USB connection. See also the parameter setting
instructions).
9 Further Settings: Password Setting
When the speed field displays PSd, it is a
prompt to enter a password. Press +/- to set the
four-figure password (using digits 0 to 9). Briefly
press i to
switch between the single digits of the pass-
word. The default password is “0512”. Briefly
press to switch between the single digits of the
password. The default password is “0512”. Briefly
press i to confirm your setting. If the set pass-
word is wrong, the system automatically returns
to the previous interface. If the set password is
correct, the system will switch to the setting of
the wheel diameter.
10 Wheel Diameter Selection
When the speed position displays Wd, press +/-
to select the correct wheel diameter: 16/18/20/
22/24/26, 700c, 28/29. The measurements are
in inches. A wrong wheel diameter can lead to
speed anomalies. Aer this setting, briefly press
(< 0.3 seconds) to enter the setting interface of
speed limit.
11 Speed Limit Setting
When the speed field displays SPL, the distance
field displays the value of the speed limit. Press
+/- i(< 0.3 seconds) to enter the menu of battery
communication.
12 Battery Communication
The speed field displays b01 and the distance
field displays the speed limit. Press i (< 0.3 se-
conds) to see the other information in sequence.
Aer thissetting, press i twice (< 0.3 seconds) to
exit the menu.
Note: Only when communication has been esta-
blished between the battery and the controller
the following information will be displayed,
otherwise the display will only show “- - - -”.
13 Information on the battery menu
Le collumn: Information Displayed in the
Speed Field; Right collumn: Explanation
b01 current temperature
b02 maximum temperature
b03 lowest temperature
b04 total voltage
b05 current
b06 average current
b07 remaining capacity
b08 full capacity
b09 relative state of charge
b10 absolute state of charge
b11 charge/discharge cycle
b12 longest period without charge
b13 period since last charge
d01 voltage cell 1
d02 voltage cell 2
dn voltage cell n
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beaufort Monte Maschio 2017 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beaufort Monte Maschio 2017 in the language / languages: English as an attachment in your email.

The manual is 0.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beaufort Monte Maschio 2017

Beaufort Monte Maschio 2017 User Manual - Dutch - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info