EN - Warning:
- The smokemachine must be placed at least 100 cm away from inflammable materials such as curtains,
books, etc. Make sure that the housing cannot be touched by accident.
- Use only Beamz water-based smoke fluid recommended by your dealer.
- Poor smoke liquid caused permanent damage, bad effect, clogging, spitting of unevaporated liquid etc.
- Never add flammable fluids (oil, gas, perfume) to the fog liquid.
- Always keep enough smoke liquid in the tank.
Use of the device without liquid will cause damage to the pump and heater.
- Do not obstruct the openings on top of the case to guarantee a good ventilation.
- Don’t put any objects on the smoke machine.
- For indoor use only.
- During installation, nobody should stand beneath the mounting area.
- Prior to the first use, have the unit checked by a qualified person.
- The unit contains voltage carrying parts. DO NOT open the smokemachine
- Never plug or unplug the unit with wet hands.
- If the plug and/or mains lead are damaged, they need to be repaired by a qualified technician.
- If the unit is damaged to an extent that you can see internal parts, do not plug the unit into a mains outlet. It
needs to be repaired by a qualified technician.
- Only connect this unit to an earthed mains outlet of 220-240Vac/50Hz .
- Always unplug the unit during a thunderstorm or when it is not in use.
- If the unit has not been used for a longer period of time, condensation can occur inside the housing. Please
let the unit reach room temperature prior to use.
- When you unplug the unit from the mains always pull the plug, never the lead.
- In order to prevent dropping of the unit, a safety fastening needs to be installed. This can be a solid chain, a
steel cable, etc. which has to be fastened separately from the mounting bracket.
- The supplied bracket is the main fixing and must be used to solidly mount the light effect.
- In order to avoid accidents in public premises, the local legal requirements and safety regulations/warnings
must be fulfilled.
- Keep out of the reach of children.
Location
Select a location where it is easy to fill the tank. It is also possible to hang the unit by means of the supplied
holder and fixing screws.
Installation and Use
Unpack the fog machine. Fill the fluid tank by means of a funnel. Plug the unit into a mains outlet. Thus the
heating element is automatically switched on. Depending on the room temperature, it takes about 2 minutes
until the working temperature is reached. Then the thermostat is clicking and the LED on the manual control
lights up. Push the switch once and the smoke machine will produce a nice thick fog. Once the smoke machine
has reached its working temperature (the LED is lit) the smoke machine can produce fog for a while. After this
period of time, the fog generator is cooled so much down that the thermostat switches off. Wait a while until the
working temperature is reached again. It is recommended to produce smoke with small pauses in between so
that the temperature is maintained and the thermostat doesn’t switch off.
Make sure that there is always enough liquid smoke contained in the tank. Use of the smoke machine without
liquid can permanently damage the unit. Once the smoke machine generates little smoke or pump generate
another 'rattling' sound i turn off the unit direct. Check the fluid level and fill the tank when it is empty, check the
hose and filter blockages and restore it. Plug in the unit and check if the problem is resolved. If problem persists,
switch unit direct off to prevent further damage and contact your dealer.
Switching the unit off
Switch the unit off by unplugging it from the mains. Otherwise the 700W heating element will draw unnecessarily
current.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BeamZ 160.438 - S700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BeamZ 160.438 - S700 in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info