REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure: Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit’s optics.
• Make sure the area below the installation place is free from unwanted persons during servicing.
• Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation.
• The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected.
• In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
• The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
• Clean with soft cloth using normal glass cleaning fluid.
• Always dry the parts carefully.
• Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.