SETTINGS
These submenus are used to adjust the system settings.
Press [MENU] to enter the main menu and then [UP] or [DOWN] until the display shows ‘SET’ . Press [ENTER].
Select one of the following submenus:
• ‘UPLD’ :
This one starts the upload (copying from the Master unit into the Slave units) of the preprogramed automatic programmes.
Password entry is necessary. To do so, press [UP]+ [DOWN]+[UP]+[DOWN] in sequence and then [ENTER]. The Slave units
signalise the upload progress:
– yellow light: upload in process
– red light: an error occurred
– green light: upload successful
• ‘REST’ :
This one resets to defaults. Password entry is necessary. To do so, press [UP]+[DOWN]+[UP] +[DOWN] in sequence and then
[ENTER].
• ‘Id’ :
This one is used to enable ( ‘on’ ) or disable ( ‘oFF’ ) the usage of the ID addressing via DMX controller.
• ‘RGBA’ :
This one determines, whether the white colour is defined by RGB=255.255.255 ( ‘Yes’ ), or is manually defined via the CAL2
menu ( ‘No’ ).
• ‘dim’ :
This one determines the dimmer mode or the speeds:
– Setting ‘oFF’ : Changes of dimmer and RGBW are done linearly.
– Settings ‘dim1’ , ‘dim2’ , ‘dim3’ ‘dim4’ : Speed modes for the non-linear dimmer; ‘dim1’
is the fastest, ‘dim4’ is the slowest.
SETTING COLOUR TEMPERATURE FOR “WHITE”
11 different preprogramed values for colour temperature ‘White’ can be edited.
Press [MENU] to enter the main menu and then [UP] or [DOWN] until the display shows ‘CAL1 white’ . Press [ENTER].
With [UP] and [DOWN] you can now call up one of the 11 predefined settings for ‘White’ ( ‘WT01’ … ‘WT11’ ).
Press [ENTER], then you can change the following values:
• R: intensity red, value range is between ‘000’ and ‘255’
• G: intensity green, value range is between ‘000’ and ‘255’
• b: intensity blue, value range is between ‘000’ and ‘255’
• W: intensity white, value range is between ‘000’ and ‘255’
DEFINING DIFFERENT VALUES FOR “WHITE”
Press [MENU] to enter the main menu and then [UP] or [DOWN] until the display shows ‘CAL2’ . Press [ENTER].
The display shows ‘REGW ’ . Press [ENTER].
You can change the following values:
• R: intensity red, value range is between ‘000’ and ‘255’
• G: intensity green, value range is between ‘000’ and ‘255’
• b: intensity blue, value range is between ‘000’ and ‘255’
ENABLING / DISABLING THE PASS-WORD
You can specify whether to enable or disable the access password. To enter the password, press [UP]+[DOWN]+[UP]+[DOWN]
in sequence and confirm with [ENTER].
Press [MENU] to enter the main menu and then [UP] or [DOWN] until the display shows ‘KEY’ . Press [ENTER].
With [UP] and [DOWN] you can now select between ‘oN’ and ‘oFF’ . Then press [ENTER].