INSTALLATION INSTRUCTIONS
GAS FLOW ADJUSTMENT
In order to adjust the minimum gas flow proceed as follows:
x
Ignite the burner and turn down to the minimum setting.
x
Remove the control knob from the gas tap.
x
Adjust the flow either clockwise to decrease or anti-clockwise to increase the flame. Use a
screwdriver inserted down the gas tap rod or via the screw head adjacent to the rod for models
fitted with a Flame Supervision Device.
x
Check that the flame is 3- 4 mm in length, bluish in colour, stable and noiseless, and does not
extinguish when changing from maximum to minimum flow.
x
Replace the control knob and check that all components have been reassembled correctly.
ELECTRICAL CONNECTION
Before connecting the appliance, make sure the supply voltage marked on the rating Plate
corresponds with the mains supply voltage.
WARNING – THIS APPLIANCE MUST BE EARTHED
This appliance should be wired into a double pole Switched Fused Spur Outlet having 3 mm
contact separation and the fuse rating reduced to 3 Amps.
IMPORTANT
The wires in the main supply lead are coloured in accordance with the following code:
Green and Yellow – Earth
Blue – Neutral
Brown – Live
The connections must be made as follows:
The wire coloured Green and Yellow must be connected to the terminal marked ‘E’ or the earth
symbol (.) or coloured green and yellow.
The wire coloured Blue must be connected to the terminal marked ‘N’ or coloured blue or Black.
The wire coloured Brown must be connected to the terminal marked ‘L’ or coloured brown or red.
NOTE: The terminals marked ‘SUPPLY’ are for the mains supply wires and the terminations
marked ‘LOAD’ are for the appliance wires.
The electrical outlet is to be positioned in an easily accessible position adjacent to the appliance. In
the event that it is necessary to replace the mains supply lead, the replacement must conform to
the specification listed in the Technical Data. Ensure that the colour code connection is correct and
that all screws are tightened correctly.
34