WATER SUPPLY
Water supply: cold water only
Tap: 3/4” threaded hose connection
Pressure: 100-1000 kPa (1-10 bar).
WATER INLET HOSE
1.
Carefully screw the hose connection onto the tap
preferably by hand. Make sure there are no kinks in
the hose.
2.
Check water-tightness of tap and appliance
connections by turning the tap completely on.
If the hose is too short, replace it with a suitable
length of pressure resistant hose (1000 kPa min,
EN 50084 approved type).
Periodically check the hose for brittleness and
cracks and replace if necessary.
The appliance can be connected without an anti-
backpressure valve.
Install the appliance in accordance with regulations
of your local water company.
WATER STOP (depends on model)
Screw the threaded connector with the filter inserted
onto the tap. Open the water tap fully and check the
water-tightness of the connection point.
The appliance must not be connected to the mixing
tap of a non-pressurized water heater.
The inlet hose and the plastic enclosure at the tap
connection contain electrical components.
N.B. Do not cut the hose and do not immerse
the plastic enclosure in water.
If the flexible hose is damaged, unplug the
appliance from the mains immediately.
If the hose is too short, replace it with a 3 m Water
Stop hose (available from After-Sales Service or
from your dealer). This operation must be carried
out exclusively by a licensed electrician.
DRAINING
Connecting the water drain hose.
Connect the drain hose to the siphon or hook it
over the edge of a sink by means of the “U” bend
(see figure).
The drain hose should not be hooked onto small
washbasins.
Max. drain height: 1.25 m
If you need to add an extension, use a flexible
hose of the same type and secure the union with
screw-on hose clips.
Max. drain hose length: 2.50 m
Important:
Make sure there are no kinks in the hose. Secure
the hose so that it cannot fall down while the
appliance is running.
INSTALLATION INSTRUCTIONS
Straight hose Water Stop hose
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bauknecht wa 7741 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bauknecht wa 7741 in the language / languages: English as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bauknecht wa 7741

Bauknecht wa 7741 User Manual - German - 18 pages

Bauknecht wa 7741 User Manual - Dutch - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info