765277
19
Zoom out
Zoom in
Previous page
1/26
Next page
TECH100 User Guide 1.42 2017
19 | Page
On the tool, select Battery Check from the Main Menu. You can then
begin the battery check by pressing the OK button.
After pressing OK, the tool will prompt to switch the ignition off, because then it measures
the ignition off system.
Next, the tool will prompt to switch the ignition on (key ON, engine OFF) and measure the
ignition on system.
Finally, the tool will prompt to start the engine and run at idle. It will take measurements for
the crank and charging systems.
Once the tool has finished all measurements, the results will be displayed.
The values of the test results are as follows:
Ignition Off:
Below 12.0V: LOW
12.0V 12.6V: GOOD
Above 12.6V: FULL
Ignition On:
Below 11V: LOW
11.0V 12.2V: GOOD
Above 12.2V: FULL
Crank:
Below 7.0V: WEAK
7.0V 10.0V: GOOD
Above 10.0V: STRONG
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bartec Tech 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bartec Tech 100 in the language / languages: English as an attachment in your email.

The manual is 2,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bartec Tech 100

Bartec Tech 100 User Manual - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info