26 Installation instructions
UNILUX-6 265 Three-sided
3.3.2 Aeration / ventilation
The appliance generates: - convection air
- combustion air
Convection air is devoted to the convection of heat from the appliance to the room.
The source of heat is in the room and stays there.
Combustion air is needed to keep the combustion going by drawing in air from the
room, of directly from outside, due to the natural draught of the chimney.
On delivery, the appliance is prepared for a combustion air supply from the living room
or a combustion air supply directly from the outside, through the underside or through
the back of the appliance.
Combustion air from the living-room:
The air inlet openings are located under the operating fl ap. When using the
appliance, please ensure there is a suf" cient supply of fresh air: use a grate with a
minimum net opening in the outer wall of 150 cm2.
Make sure that the ventilation supply is open; this is particularly important with
today’s airtight dwellings.
If the dwelling has mechanical ventilation that creates under pressure in the room
where the appliance is located, it is necessary to fi t a fl ue gas fan.
The type of fl ue gas fan is dependent on the capacity of the mechanical ventilation
system. Always consult your fi tter about this.
In dwellings with an operating extractor hood, this should be turned to the lowest
setting or turned off altogether. If the extractor hood remains in use, additional
ventilation must be provided in compensation. This will not only avoid poor
combustion, but will also prevent fl ue gases being sucked from the appliance into
the room.
Should creating an extra ventilation opening prove insuffi cient, it is then necessary
to fi t a fl ue gas fan.
Combustion air directly from outside:
The appliance now has a completely closed combustion syst
em
, which allows it to
operate independently of the surrounding air in the room where the appliance is
located.
The combustion air supply can be connected to the back or the underside of the
appliance. To do this, use combustion air connection Ø125 mm (exterior) for the back
or underside. Install a fi xed or fl exible pipe of Ø125 mm in the wall/fl oor between this
air supply connection and outside air supply inlet. We recommend that this pipe is
tted with a sealing valve in order to prevent condensation in the appliance when it
is not in use.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Barbas UNILUX-6 265 Three-sided at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Barbas UNILUX-6 265 Three-sided in the language / languages: English as an attachment in your email.

The manual is 2.25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Barbas UNILUX-6 265 Three-sided

Barbas UNILUX-6 265 Three-sided User Manual - English - 32 pages

Barbas UNILUX-6 265 Three-sided Installation Guide - German - 44 pages

Barbas UNILUX-6 265 Three-sided User Manual - German - 32 pages

Barbas UNILUX-6 265 Three-sided Installation Guide - Dutch - 44 pages

Barbas UNILUX-6 265 Three-sided User Manual - Dutch - 32 pages

Barbas UNILUX-6 265 Three-sided Installation Guide - French - 44 pages

Barbas UNILUX-6 265 Three-sided User Manual - French - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info