4 Requirements
4.1 Requirements on the location
Never use combustible building materials for the fireplace.
Do not install the appliance against a flammable rear wall.
Install a non-flammable insulation plate of at least 12 mm between the appliance and
a non-flammable rear wall. The insulation plate must cover the entire area of the rear
of the appliance.
For details about the installation, minimum clearances to flammable materials,
permitted insulation materials and air gaps, refer to the "installation and maintenance
manual".
If the fire burns in the appliance, make sure that the floor temperatures below and in
front of the appliance cannot be higher than 85 °C .
Make sure that the room where the appliance is installed is properly ventilated.
4.2 Requirements on the convection package (option)
The convection outlet opening must be at least 0,5 meter above the appliance.
No flammable material is present within 10 cm on both sides and 20 cm above the
convection outlet opening.
The convection outlet opening must be at least 15 cm below the ceiling.
4.3 Other requirements
The gas supply connection is located near the right side of the appliance for an easy
connection.
Only use gas piping of at least ½" and a shut-off valve to connect the gas supply to the
gas connection of the appliance.
Make sure that there is a wall socket with an earth connection nearby the appliance.
The socket must be accessible at all times. The power cable (+/- 0.5 m) is coming
from the right side of the appliance.
Install the fireplace on a solid floor that can bear the weight of the appliance and the
fireplace.
If the floor is made of flammable material, take correct safety measures. Install a
temperature protection plate made of nonflammable material between the appliance
and the floor.
Install the appliance as a built-in appliance in a new fireplace.
If the concentric flue system is installed in an existing chimney that is used for wood or
coal fire, clean the chimney.
If you built a new fireplace, make sure that it is ventilated with vents at the bottom and
top of the fireplace. If the fireplace is not ventilated the temperature of the appliance
can increase to dangerous temperatures and damage the fireplace.
Keep a minimum distance between the appliance and flammable mantelpieces. Refer
to the chapter "Mantelpiece clearances" in the "installation and maintenance manual":
for the correct minimum clearances.
Requirements
Gas Fire Front 70-75 7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Barbas Gas Fire Front 70-75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Barbas Gas Fire Front 70-75 in the language / languages: English as an attachment in your email.

The manual is 8.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Barbas Gas Fire Front 70-75

Barbas Gas Fire Front 70-75 Installation Guide - English - 84 pages

Barbas Gas Fire Front 70-75 User Manual - English - 36 pages

Barbas Gas Fire Front 70-75 Additional guide - German - 100 pages

Barbas Gas Fire Front 70-75 Installation Guide - German - 92 pages

Barbas Gas Fire Front 70-75 User Manual - German - 40 pages

Barbas Gas Fire Front 70-75 Additional guide - Dutch - 100 pages

Barbas Gas Fire Front 70-75 Installation Guide - Dutch - 88 pages

Barbas Gas Fire Front 70-75 User Manual - Dutch - 36 pages

Barbas Gas Fire Front 70-75 Additional guide - French - 100 pages

Barbas Gas Fire Front 70-75 Installation Guide - French - 88 pages

Barbas Gas Fire Front 70-75 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info