812716
12
Zoom out
Zoom in
Previous page
1/36
Next page
3 Safety
3.1 Safety devices on the appliance
Name Description
Thermo-electric pilot light shut off Prevents unforseen discharge of gas from the main
burner.
Overpressure hatch If an overpressure occurs in the appliance, the hatch
opens for a short duration. When the hatch opens, a
loud noise can occur. If an overpressure occurs, the in-
staller must do a thorough check on the appliance.
Overpressure door
(Only on 'Floating Frame (+)' door)
If an overpressure occurs in the appliance, the door
opens for a short duration. When the door opens, a
loud noise can occur. If an overpressure occurs, the in-
staller must do a thorough check on the appliance.
3.2 Safety instructions for operation
Warning:
Do not put flammable items within 100 cm of the appliance.
Do not use the appliance when the glass is removed.
Do not use flammable fuels on the ceramic logs.
Make sure that children are supervised when they can reach the
appliance.
Use a fire screen for heat protection.
Make sure that there is sufficient ventilation in the room in which the
appliance is installed.
Do not use the appliance is case of visual glass damage.
Make sure that the appliance is installed correctly. Refer to the Installation
and Maintenance manual.
Make sure that the appliance is installed and connected as a 'room
sealedsystem' appliance by a certified and registered gas
installationengineer.
Caution:
Make sure that embers, vermiculite granules, ceramic logs or pebbles do
not touch the pilot light burner.
Make sure that the pilot light burner is not blocked.
Do not adjust the position of embers, vermiculite granules, ceramic logs or
pebbles on the main burner.
Keep the remote control in a dry and cool place away from direct sunlight.
Clean the glass when it is dirty. If the glass is not cleaned when it is dirty
the glass can become permanently dull.
Make sure that the yearly maintenance is done.
Do not use the appliance for 4 weeks after installation. This time is
necessary for the building materials to set.
Note:
If you do not use the appliance for an extended period of time, close the
gas supply.
We recommend to set the appliance to stand-by mode (only the pilot light
burns) during winter to prevent condensation in the appliance. Refer to the
last Note of chapter
4.3.1
Safety
12 Gas Fire Front 110-60
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Barbas Gas Fire Front 110-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Barbas Gas Fire Front 110-60 in the language / languages: English as an attachment in your email.

The manual is 3.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Barbas Gas Fire Front 110-60

Barbas Gas Fire Front 110-60 Additional guide - English - 96 pages

Barbas Gas Fire Front 110-60 Installation Guide - English - 84 pages

Barbas Gas Fire Front 110-60 Additional guide - German - 100 pages

Barbas Gas Fire Front 110-60 Installation Guide - German - 92 pages

Barbas Gas Fire Front 110-60 User Manual - German - 40 pages

Barbas Gas Fire Front 110-60 Additional guide - Dutch - 100 pages

Barbas Gas Fire Front 110-60 Installation Guide - Dutch - 88 pages

Barbas Gas Fire Front 110-60 User Manual - Dutch - 40 pages

Barbas Gas Fire Front 110-60 Additional guide - French - 100 pages

Barbas Gas Fire Front 110-60 Installation Guide - French - 88 pages

Barbas Gas Fire Front 110-60 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info