Note:
It is possible to install the appliance without external air supply and take
combustion air from the installation room. If so, make sure the combustion
air inlet on the appliance is not blocked and the ventilation air inlets are
according the requirements. Refer to section
6.4
for dimensions of the
ventilation air openings.
The appliance is a room-sealed appliance when combustion air comes
from the outer side of the building through a flexible pipe that is connected
to one of these:
the combustion air inlet under the appliance.
the combustion air inlet on the combustion air box.
the combustion air inlet on the convection ventilator / combustion air
box.
If not connected to one of these three possibilities, the appliance is not a
room-sealed appliance and the data for leak tightness as given in section
11
are not valid.
It is strongly recommended to install a valve in the external combustion
air supply pipe, to avoid debris in the pipe and to avoid water vapor
condensation in the appliance when not in use.
Connection direct under the appliance, refer to section
8.7.1
.
Connection on the combustion air box, refer to section
8.7.2
.
8.7.1 Connection direct on the appliance
1. Make a hole in the outer wall or floor with a diameter of minimum 125 mm.
2. Install a grate in the hole in the outer wall. A grate is not needed when the
combustion air supply comes from the crawl space under the floor.
3. Put a 125 mm flexible aluminum
pipe over the combustion air supply
connector
4. Secure the connection with a clamp.
5. Connect the other end of the flexible
aluminum pipe with the hole in the
floor of with the grate in the wall. Use
a suitable connector.
8.7.2 Connection on the combustion air box
1. Identify the location in the outer wall or in the floor (to a ventilated crawl space) for
the external combustion air supply inlet.
2. Make a hole in the outer wall or floor with a diameter of minimum 125 mm.
3. Install a grate in the hole in the outer wall. A grate is not needed when the
combustion air supply comes from the crawl space under the floor.
Note: The image shows the combined convection ventilator / combustion
air inlet box.
Installation in a new fireplace
Cuatro-7 60-60 41
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Barbas Cuatro-7 60-60 Opti-Air at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Barbas Cuatro-7 60-60 Opti-Air in the language / languages: English as an attachment in your email.

The manual is 7.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Barbas Cuatro-7 60-60 Opti-Air

Barbas Cuatro-7 60-60 Opti-Air User Manual - English - 36 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - German - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - German - 40 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - Dutch - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - Dutch - 36 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - French - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info