6 Installation requirements
6.1 Requirements on the installation of the appliance in an existing
fireplace
This section refers to the installation of the appliance in an existing open (masonry)
fireplace.
Make sure that the location agrees with the safety requirements. Refer to section
4.1
Make sure the opening in the fireplace is large enough for a gap of 1 - 3 cm between
the appliance and the inner fireplace walls .
Make sure the floor can support the weight of the appliance. Refer to section
11
for
the weight of the appliance.
Make sure that the floor temperatures in front of the appliance cannot be higher than
85 °C, during use of the appliance. Refer to section
5.8
.
The non-combustible floor in front of the appliance must have a width that extends at
least 150 mm from each side of the appliance and a minimum depth in front of the
appliance according the requirements in section
5.8
.
Make sure the room where the appliance is installed is properly ventilated.
Make sure that combustion air can flow into the appliance without obstruction.
If applicable, install a valve in the external combustion air pipe.
The carbon monoxide alarm must be fitted and fixed in place within the same room as
the appliance and can be placed either on the ceiling or wall between 1 meter and 3
meter horizontally from the appliance. If fitting to the ceiling it must be at least 300mm
from any wall. If fitting to a wall, it must be placed as high as possible above any doors
or windows at 150mm below the ceiling.
6.2 Requirements on the installation of the appliance in a new
fireplace
Make sure the floor is made of concrete or a solid pedestal of nonflammable material.
Make sure that the floor temperatures under and in front of the appliance are
maximum 85 °C, during use of the appliance. Refer to section
5.3
and section
5.8
.
Make sure that the location agrees with the safety requirements. Refer to section
4.1
.
Do not install the appliance against a combustible rear wall or combustible side wall.
Make sure to obey the clearances as listed in section
5
.
Make sure the floor can support the weight of the appliance. Refer to section
11
for
the weight of the appliance.
Make sure the room where the appliance is installed is properly ventilated.
Make sure that combustion air can flow into the appliance without obstruction.
If applicable, install a valve in the external combustion air pipe.
If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
Make sure there is an earthed wall socket for the power supply of the convection
ventilator and an earthed wall socket for the power supply of the Opti-Air system.
These sockets must be accessible at all times.
Make sure the distance between the convection air outlet openings and the ceiling
above is minimum 50 cm.
Make sure the distance between the convection air outlet openings and a neighboring
wall is minimum 20 cm.
Installation requirements
32 Cuatro-7 60-60
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Barbas Cuatro-7 60-60 Opti-Air at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Barbas Cuatro-7 60-60 Opti-Air in the language / languages: English as an attachment in your email.

The manual is 7.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Barbas Cuatro-7 60-60 Opti-Air

Barbas Cuatro-7 60-60 Opti-Air User Manual - English - 36 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - German - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - German - 40 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - Dutch - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - Dutch - 36 pages

Barbas Cuatro-7 60-60 Opti-Air Installation Guide - French - 92 pages

Barbas Cuatro-7 60-60 Opti-Air User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info