Operating the display | ZM Series User Manual
Option Sub option Range Description
Conguration Power
Control
Slave,
Master
In slave mode monitor will turn on if 12/24V is
detected on the yellow wire. In master mode
monitor will turn on slave devices by switching 12V
to yellow wire when monitor is on
Key Beeps O, On Turns on or o the OSD key beeps
Factory
Reset
Yes, No Restore all settings to default
Option Sub option Description
Touch Screen HDMI Enables serial touch control for HDMI
DVI Enables serial touch control for DVI
Enable All Enables serial touch control for HDMI and DVI
Disable Disables serial touch control
¼ Note: USB touch control is automatically enabled upon connection.
Updating the rmware
Updates to the ZM series monitor rmware may occasionally become available. The updates
will typically include improvements to existing functionality or new features, and will be made
available via the B&G website: www.bandg.com.
Checking current rmware version
On the Conguration page it is possible to see the name of the monitor, resolution (native),
OSD version, BIOS version, and the serial number.
Installing an Update
Updates should be loaded via a compatible B&G Multifunction display. Refer to the applicable
product manual on how to upgrade a device over NMEA 2000.
Alternatively, return the device to a Navico dealer to arrange updating.
¼ Note: Upgrading a ZM monitor can only be done one at a time.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BandG ZM Series Monitors at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BandG ZM Series Monitors in the language / languages: English as an attachment in your email.

The manual is 5,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of BandG ZM Series Monitors

BandG ZM Series Monitors User Manual - German - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info