764828
6
Zoom out
Zoom in
Previous page
1/26
Next page
42339 rev A 11-06-19
6
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370,
6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and
domestic applied for and pending. All material copyright of Balboa Water Group.
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is
known as the “primary pump.”
The primary pump can be either a 2-Speed Pump 1 or a circulation pump.
If the primary pump is a 2-Speed Pump 1, Ready Mode (indicated by ) will circulate water periodically, using Pump 1
Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. This is known
as “polling.”
Rest Mode (indicated by ) will only allow heating during programmed filter cycles. Since polling does not occur, the
temperature display may not show a current temperature until the primary pump has been running for a minute or two.
Circulation Mode (See Page 4, under Pumps, for other circulation modes)
If the spa is configured for 24HR circulation, the primary pump generally runs continuously. Since the primary pump is
always running, the spa will maintain set temperature and heat as needed in Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed filter times, even though the water is being
filtered constantly when in Circulation Mode.
Ready-in-Rest Mode
appears in the display if the spa is in Rest Mode and “Jets” is pressed. It is assumed that the spa is being used and
will heat to set temperature. The primary pump will run until set temperature is reached, or 1 hour has passed. After 1 hour,
the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and changing the Mode.
Mode – Ready and Rest
Sub-Menu Detail – MODE – Ready and Rest
Ready Mode will allow the spa to Poll and determine a need for heat. The panel will maintain a “current” temperature display.
Rest Mode will not Poll and will only heat during filter cycles. The panel will not display a current temperature at all times.
The Main Screen will display RUN PUMP FOR TEMP if the primary pump has not run for over 1 hour.
The Main Screen will display normally during Filter Cycles or when the spa is in use.
If the primary pump has been off for an hour or more, when any function button, EXCEPT Light, is pressed on the panel,
the pump used in conjuncton with the heater will run so that temperature can be sensed and displayed.
1 Hour
04-11-09
Press Menu/Select
repeatedly until MODE
appears in the LCD.
Main Screen
Main Screen
Main Screen
To Set
Toggle between Ready (indicated by ) and Rest (indicated by ).
Pressing Menu/Select when the display is toggled will go to Main Screen.
To next item in
Main Menu
If not toggled
*****
Waiting a few
seconds reverts to
original settings
MODE
RUN PUMP TEMP ----
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Menu/Select button
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
*****
Sub-Menu Detail – MODE – Ready-in-Rest
04-11-09
Main Screen
Press “Jets” button
Main Screen
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Balboa TP500S Control Panel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Balboa TP500S Control Panel in the language / languages: English as an attachment in your email.

The manual is 5,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Balboa TP500S Control Panel

Balboa TP500S Control Panel User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info