Adjusting Filtration
Sets Filter 1 length in hours
Sets start hour Selects minutes
Selects part of an hour
SET FLTR1 PSET FLTR1 PSET FLTR1 P
Sets 15-minute increments
SET FLTR1 P
FLTR1
FLTR1 SET FLTR1 SET FLTR1 SET FLTR1
Shows/flashes start time
FLTR1
Sub-Menu Detail – Set Filter Cycle 1
to show RUN HRS
to show F1 ENDS xx:xx
Sets 15-minute increments
A
1
While the Temperature is
still flashing, press Light
repeatedly until FLTR 1
appears in the LCD.
SET RANGE
Main Screen
READY RANGE FLTR1
Main Screen
READY RANGE FLTR1
Sets Filter 1 length in hours
Sets start hour Selects minutes
Selects part of an hour
SET FLTR 2PSET FLTR 2PSET FLTR 2 P
Sets 15-minute increments
SET FLTR 2 P
FLTR 2
FLTR 2SET FLTR 2SET FLTR 2SET FLTR 2
Shows/flashes start time
FLTR 2
to show RUN HRS
to show F1 ENDS xx:xx
Sets 15-minute increments
A
Main Screen
READY RANGE FLTR1
2
To next item in
Main Menu
Main Screen
READY RANGE FLTR1
SET FLTR 2SET FLTR 2
To Set
To Set
To Set
To Set
To Set
Waiting
a few seconds
reverts to original setting
Waiting
a few seconds
reverts to original setting
Wait to
Revert
*****
Waiting
a few seconds
reverts to original setting
*****
Waiting a few seconds
will lose any new Filter 1
Start Time and Run Hours and
revert to the previous Filter 1 settings.
*****
To Set
Waiting a few seconds
will lose any new Filter 2 On/OFF,
Start Time and Run Hours and
revert to any previous Filter 2 settings.
*****
*****
Wait to
Revert
*****
*****
Main Filtration
Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of
the display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calcu-
lates the end time and displays it automatically.
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
*****
Filter Cycle 2 - Optional Filtration
Filter Cycle 2 is OFF by default.
It is possible to overlap Filter Cycle 1 and Filter
Cycle 2, which will shorten overall filtration by the
overlap amount.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/
or a Blower will purge water from their respective plumbing by
running briefly at the beginning of each filter cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will
initiate a purge when Filter Cycle 2 is programmed to begin.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Balboa TP400 Display at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Balboa TP400 Display in the language / languages: English as an attachment in your email.

The manual is 3,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Balboa TP400 Display

Balboa TP400 Display User Manual - German - 25 pages

Balboa TP400 Display User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info