AXIS P33 Series - System Options
System Options
Security
Users
User access control is enabled by default. An administrator can set up other users, by giving them user names and passwords.
It is also possible to allow anonymous viewer login, which means that anybody may access the Live View page:
The user list displays the authorized users and user groups (levels):
HTTP/RTSP Password Settings - Select the type of password. You may need to allow unencrypted passwords if there are
viewing clients that do not support encryption, or if you recently upgraded the firmware and the existing clients support
encryption, but need to log in again, and be configured to use this functionality.
User Settings - Check the option your require.
Enabling anonymous viewer login - allows any viewer direct access to the Live View page.
The Enable anonymous PTZ control login option allows anonymous users to join a queue for gaining control of the
PTZ controls provided by the Network Camera. See PTZ, on page 27 for more information on Pan Tilt Zoom settings.
Enable Basic Setup - Before using the Network Camera, there are certain settings that should be defined, most of
which require Administrator access privileges. You can quickly access these settings through Basic Setup in the menu.
All settings are also available from the standard Setup link in the menu. Basic Setup is enabled by default but can be
disabled and removed from the menu.
IP Address Filter
Enable IP Address Filtering to allow or deny access to the network cameras. Once enabled, the IP addresses in the list are
allowed or denied access according to the choice made in the drop-down list Allow/Deny the following IP addresses.
The administrator can add up to 256 IP address entries to the list (a single entry can contain multiple IP addresses). The users
from these IP addresses need to be specified in the user list with the appropriate access rights. This is done from Setup >
System Options > Security > Users.
HTTPS
The network cameras support encrypted browsing using HTTPS.
A self-signed certificate can be used until a Certificate Authority-issued certificate has been obtained. Click the Create
self-signed Certificate button to install a self-signed certificate. Although self-signed certificates are free and offer some
protection, true security is only implemented after the installation of a signed certificate issued by a certificate authority.
A signed certificate can be obtained from an issuing Certificate Authority by clicking the Create Certificate Request button.
When the signed certificate is returned, click the Install signed certificate button to import the certificate. The properties of
any certificate request currently resident in the camera or installed can also be viewed by clicking the Properties... button. The
HTTPS Connection Policy must also be set in the drop-down lists to enable HTTPS in the camera.
For more information, please refer to the online help .
Viewer Provides the lowest level of access, which only allows access to the Live View page.
Operator An operator can view the Live View page, create and modify events, and adjust certain other settings.
Operators have no access to System Options.
Administrator An administrator has unrestricted access to all menus for configuration and can determine the
registration of all other users.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Axis P3344 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Axis P3344 in the language / languages: English as an attachment in your email.

The manual is 7,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info