293178
5
Zoom out
Zoom in
Previous page
1/73
Next page
AXIS 207/207W/207MW Installation Guide Page 5
ENGLISH
ENGLISH
Unit connectors
Network connector - RJ-45 Ethernet connector. Supports Auto-MDIX (AXIS 207W/MW
only) for automatic detection of straight or crossover cable. Using shielded cables is
recommended.
Power connector - Mini DC connector. 4.9-5.1V DC, max 4.0W. See product label for
±
connection.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering,
time lapse recording, alarm notifications, etc. It provides the interface to:
1 transistor output - For connecting external devices such as relays and LED:s.
Connected devices can be activated by Output buttons on the Live View page or
by an Event Type. The output will show as active (in Event Configuration > Port
Status) if the alarm device is activated.
1 digital input - An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under Event Configuration > Port Status).
Auxiliary power and GND
Function Pin number Notes Specifications
Transistor
Output
Pin 4 Uses an open-collector NPN
transistor with the emitter con-
nected to the GND pin. If used
with an external relay, a diode
must be connected in parallel
with the load, for protection
against voltage transients.
Max load = 100mA
Max voltage = 24V DC
(to the transistor)
Digital Input Pin 3 Connect to GND to activate, or
leave floating (or unconnected)
to deactivate.
Must not be exposed to
voltages greater than
10V DC
GND AXIS 207 = Pin 2
AXIS 207W/MW = Pin 1
Ground
Auxiliary DC
Power Input
AXIS 207 = Pin 1
AXIS 207W/MW = Pin 2
Electrically connected in parallel
with the connector for the power
supply, this pin provides an
auxiliary connector for mains
power to the unit.
This pin can also be used to
power auxiliary equipment, with
a maximum current of 50mA.
Voltage = 4.9-5.1V DC
(all models)
Min power:
AXIS 207: 2.5W
AXIS 207W: 3.5W
AXIS 207MW: 4.0W
Pin layouts
1
4
1
4
AXIS 207MW
AXIS 207W
AXIS 207
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Axis 207w us at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Axis 207w us in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info