293183
36
Zoom out
Zoom in
Previous page
1/54
Next page
36
AXIS 207 - The I/O Terminal Connector
The I/O Terminal Connector
Pinout and Interface
The 4-pin I/O terminal connector provides the interface to:
1 transistor output
1 digital input
auxiliary power and GND
The terminal connector is used in applications for e.g. motion detection, event triggering,
time lapse recording, alarm notification via email, etc.
Input - for connecting e.g. a pushbutton. If the pushbutton is pressed, the state
changes and the input becomes active (shown under Event Configuration > Port
Status).
Output - connects e.g. an alarm device that can be activated by Output buttons
on the Live View page, or by an Event Type. The output will show as active
(Event Configuration > Port Status) if the alarm device is activated.
Function Pin Description Pinouts
Transistor
Output
4 With a maximum load of 100mA and a
maximum voltage of 24V DC, this output
has an open-collector NPN transistor with
the emitter connected to the GND pin. If
used with an external relay, a diode must be
connected in parallel with the load, for pro
-
tection against voltage transients.
The I/O terminal pins on the
AXIS 207 are numbered as
shown below.
4
1
Digital Input 3 Connect to GND to activate, or leave float-
ing (or unconnected) to deactivate.
GND 2
Auxiliary DC
Power Input
1 5VDC/min 2.5W. Electrically connected in
parallel with the connector for the PS-L
power adapter, this pin provides an auxiliary
connector for mains power to the unit. This
pin can also be used to power auxiliary
equipment, max 50mA.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Axis 207 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Axis 207 in the language / languages: English as an attachment in your email.

The manual is 1,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info