AXIS 207 Network Camera
User’s Manual
AXIS COMMUNICATIONS
<Product Name> Quick User’s Guide
About this Document
This manual is intended for administrators and users of the
AXIS 207 Network Camera, and is applicable for software
release 4.40 and later. It includes instructions for using and
managing the AXIS 207 on your network. Previous
experience of networking will be of use when using this
product. Some knowledge of UNIX or Linux-based systems
may also be beneficial, for developing shell scripts and
applications. Later versions of this document will be posted to
the Axis Website, as required. See also the product’s online
help, available via the Web-based interface.
Safety Notices Used In This Manual
Caution! - Indicates a potential hazard that can damage the
product.
Important! - Indicates a hazard that can seriously impair
operation.
Do not proceed beyond any of the above notices until you
have fully understood the implications.
Intellectual Property Rights
Axis AB has intellectual property rights relating to
technology embodied in the product described in this
document. In particular, and without limitation, these
intellectual property rights may include one or more of the
patents listed at http://www.axis.com/patent.htm and one or
more additional patents or pending patent applications in the
US and other countries.
This product contains licensed third-party software. See the
menu item “About” in the product’s user interface for more
information.
This product contains source code copyright Apple Computer,
Inc., under the terms of Apple Public Source License 2.0 (see
http://www.opensource.apple.com/apsl/).
The source code is available from:
http://developer.apple.com/darwin/projects/bonjour/
Legal Considerations
Video and audio surveillance can be prohibited by laws that
vary from country to country. Check the laws in your local
region before using this product for surveillance purposes.
This product includes one (1) MPEG-4 decoder license. To
purchase further licenses, contact your reseller.
Electromagnetic Compatibility (EMC)
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna. Increase the
separation between the equipment and receiver. Connect the
equipment to an outlet on a different circuit to the receiver.
Consult your dealer or an experienced radio/TV technician
for help. Shielded (STP) network cables must be used with
this unit to ensure compliance with EMC standards.
USA - This equipment has been tested and found to comply
with the limits for a Class B computing device pursuant to
Subpart B of Part 15 of FCC rules, which are designed to
provide reasonable protection against such interference when
operated in a commercial environment. Operation of this
equipment in a residential area is likely to cause interference,
in which case the user at his/her own expense will be
required to take whatever measures may be required to
correct the interference.
Canada - This Class B digital apparatus complies with Canadian
ICES-003.
Europe - This digital equipment fulfills the requirements
for radiated emission according to limit B of EN55022/1998, and
the requirements for immunity according to EN55024/1998
residential, commercial, and light industry.
Japan - This is a class B product based on the standard of the
Voluntary Control Council for Interference from Information
Technology Equipment (VCCI). If this is used near a radio or
television receiver in a domestic environment, it may cause radio
interference. Install and use the equipment according to the
instruction manual.
Australia - This electronic device meets the requirements of the
Radio communications (Electromagnetic Compatibility) Standard
1998 AS/NZS 3548.
Safety
Compies to EN 60950, Safety of Information Technology
equipment.
Equipment Modifications
This equipment must be installed and used in strict accordance
with the instructions given in the user documentation. This
equipment contains no user-serviceable components.
Unauthorized equipment changes or modifications will
invalidate all applicable regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of this manual.
Please inform your local Axis office of any inaccuracies or
omissions. Axis Communications AB cannot be held responsible
for any technical or typographical errors and reserves the right to
make changes to the product and manuals without prior notice.
Axis Communications AB makes no warranty of any kind with
regard to the material contained within this document, including,
but not limited to, the implied warranties of merchantability and
fitness for a particular purpose. Axis Communications AB shall
not be liable nor responsible for incidental or consequential
damages in connection with the furnishing, performance or use of
this material.
Trademark Acknowledgments
ActiveX, Apple, Boa, Ethernet, Internet Explorer, Linux,
Microsoft, Mozilla, Netscape Navigator, OS/2, Real, QuickTime,
UNIX, Windows, WWW are registered trademarks of the
respective holders. Java and all Java-based trademarks and logos
are trademarks or registered trademarks of Sun Microsystems, Inc.
in the United States and other countries. Axis Communications
AB is independent of Sun Microsystems Inc.
UPnP
TM
is a certification mark of the UPnP
TM
Implementers
Corporation. Bonjour is a trademark of Apple Computer Inc.
This product includes MPEG-4 AAC audio coding technology
licensed by Fraunhofer IIS. Refer to FHG audio home page
http://www.iis.fraunhofer.de/amm/
Support
Should you require any technical assistance, please contact your
Axis reseller. If your questions cannot be answered immediately,
your reseller will forward your queries through the appropriate
channels to ensure a rapid response. If you are connected to the
Internet, you can:
• download user documentation and firmware updates
• find answers to resolved problems in the FAQ database. Search
by product, category, or phrases
• report problems to Axis support by logging in to your private
support area
• visit Axis Support at www.axis.com/techsup/
AXIS 207 User’s Manual Rev.3.0
Part No: 25384r6
August 2006
Copyright© Axis Communications AB, 2005-2006
4
AXIS 207
Contents
Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Key features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Accessing the Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Access from a browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting the Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accessing the camera from the Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3GPP Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Focusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
The Live View Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Video Streams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
How to stream MPEG-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
MPEG-4 clients. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Motion JPEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Accessing the Setup tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
AXIS Media Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Video and Image settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Audio Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Live View Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
HTML Examples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Event Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Port Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
System Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Date & Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Network - Basic TCP/IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Network - Advanced TCP/IP Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
QoS (Quality of service) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SMTP (email) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
UPnP™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
RTP / MPEG-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Bonjour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Ports & Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5
AXIS 207
LED Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Advanced. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
The I/O Terminal Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6
AXIS 207 - Product Features
Product Features
The AXIS 207 is the world’s smallest true MPEG-4 network camera, from Axis
Communications - the market leader in network video.
Key features
True MPEG-4 image compression for optimized bandwidth efficiency
Motion detection for bandwidth efficiency
Built-in Web server for remote monitoring and surveillance
Support for Quality of Service (QoS)
Built-in microphone for one-way audio
Excellent low light performance down to 1 lux
Superior image quality with 30 fps in full VGA resolution
Compatible with PDAs/cell phones using 3GPP mediaplayers
Multilevel password protection for restricting camera access
NAT-Traversal, which allows a camera located on an intranet (LAN) to be made
available from the other (WAN) side of a NAT router
Support for UPnP™
Support for Bonjour
Supplied with stand, clamp, application software (ACE) and a fixed iris lens. For indoor use
only.
UPnP™ is a certification mark of the UPnP
Implementers Corporation.
7
AXIS 207 - Product Features
Overview
Lock ring
Network
connector
Network
indicator
Control
button
Product ID &
serial number
(S/N) label
Power
indicator
I/O terminal
connector
Power
connector
Focus ring
Status
indicator
(outer ring)
Microphone
Microphone - Built-in microphone for one way MPEG-4, ISMA, 3GPP compatible audio.
Power Connector - For connection of the PS-L power adapter (included).
I/O Connector - The I/O terminal connector provides the physical interface to one
transistor output, one digital input and an auxiliary connection point for DC power. For
more information, see
The I/O Terminal Connector, on page 36.
Network Connector - The AXIS 207 connects to the network via a standard network cable,
and automatically detects the speed of the local network segment (10BaseT/100BaseTX
Ethernet).
Product ID & Serial Number Label - The serial number may be required during
installation.
Control Button - Press this button to install using the AXIS Internet Dynamic DNS Service,
or to restore the factory default settings, as described in
Resetting to the Factory Default
Settings, on page 35.
8
AXIS 207 - Product Features
LED indicators
After completion of the startup and self test routines, the multi-colored Network, Status,
and Power LED indicators flash as follows:
Amber Steady for connection to a 10 Mbit/s network. Flashes for network activity.
Green Steady for connection to a 100 Mbit/s network. Flashes for network activity.
Unlit No network connection.
Green Steady for normal operation. Can be configured to flash green at intervals whenever the
camera is accessed. See the online help for more information.
Unlit When configured for “no flash” on camera access.
Amber Steady during startup, reset to factory default or when restoring settings.
Red Slow flash for failed upgrade.
Green Normal operation.
Amber Flashes green/amber during firmware upgrade.
Network
Status
Power
9
AXIS 207 - Accessing the Camera
Accessing the Camera
Before accessing the camera it must be installed. Please see the installation guide supplied
with your product.
The camera can be used with most standard operating systems and browsers. The
recommended browser is Microsoft Internet Explorer with Windows, Safari with Macintosh
and Mozilla with other operating systems.
Notes: To view streaming video in Microsoft Internet Explorer, set your browser to allow ActiveX controls and
allow the AXIS Media Control (AMC) to be installed on your workstation.
QuickTime
TM
and Real Player
TM
are also supported for viewing streaming MPEG-4 video and audio.
If your workstation restricts the use of additional software components, the camera can be configured to
use a Java applet for viewing motion JPEG.
The AXIS 207 includes one (1) decoder license for viewing MPEG-4 video streams. This is automatically
installed with AMC. The administrator can disable the installation of the MPEG-4 decoder, to prevent
unlicensed copies being installed.
Access from a browser
1. Start a browser (e.g. Internet Explorer,
Mozilla)
2. Enter the IP address or host name of the camera in the Location/Address field of
your browser.
To access the camera from a Macintosh computer (Mac OSX), simply click on the
Bonjour tab and select the AXIS 207 from the drop-down list.
3. If this is the first time the camera is accessed, see Setting the Password, on page
10. Otherwise enter your user name and password, as set by the administrator.
4. The camera’s Live View page is now displayed in your browser.
Note:
The layout of the Live View page may have been customized to specific requirements. Consequently, some
of the examples and functions featured here may differ from those displayed on your own Live View page.
10
AXIS 207 - Accessing the Camera
Setting the Password
1. When accessing the camera for the first
time, the ‘Configure Root Password
dialog will be displayed on the screen.
2. Enter a password and then re-enter it, to
confirm the spelling. Click OK.
3. The ‘Enter Network Password’ dialog
will appear. Enter the User name: root
Note: The default administrator user name root is permanent and cannot be
deleted.
4. Enter the password as set in step 2 above, and click OK. If the password is lost,
the camera must be reset to the factory default settings. See page 35.
5. If required, click Yes to install the AXIS Media Control (AMC). You will need
administrator rights on the computer to do this.
Accessing the camera from the Internet
Once installed, the camera is accessible on your local network (LAN). To access the camera
from the Internet you must configure your broadband router to allow incoming data traffic
to the camera. To do this, enable the NAT-traversal feature, which will attempt to
automatically configure the router to allow access to the camera. This is enabled from
Setup > System Options > Network > TCP/IP Advanced.
For more information, please see NAT traversal (port mapping), on page 30. See also the
AXIS Internet Dynamic DNS Service at www.axiscam.net or, for Technical notes on this
and other topics, visit the Axis Support Web at www.axis.com/techsup
3GPP Compatibility
The AXIS 207 is 3GPP compatible by default. To view live video over 3GPP:
Contact your cell phone provider and make sure that the configuration is correct. It
is highly recommended that you have an account with a public IP address.
Check that the AXIS 207 has a completely public IP address, i.e. no ports blocked
by a firewall.
•In Setup > Video & Image > Image Appearance, set the Resolution to 160x120 or
176x144
•In Setup > Video & Image > Advanced > MPEG-4 > Bit Rate Control, set the
Maximum Bit Rate to 64 or 128 kbit/s
•In Setup > Video & Image > Advanced > MPEG-4 > GOV Settings, set the Length
to 8.
11
AXIS 207 - Accessing the Camera
Focusing
Status Indicator
Focus Ring
To focus:
Open a browser and
examine the image. If
required, adjust the focus
ring until the focus is
satisfactory.
Small dot above the lens
assembly.
Note: Upon delivery, the raised line on the focus ring is aligned with the dot above the lens, and the focus is
set to infinity.
(outer ring)
(inner ring)
Raised line
on focus ring.
The Live View Page
Depending on whether or not the Live View page has been customized, the buttons
described below may or may not be visible.
The Video Format drop-down list allows the video format on the Live
View page to be temporarily changed.
The Output buttons control the
output directly from the Live
View page. These buttons are
configured under Setup > Live
View Config > Layout.
Pulse - click this button to activate the
output for a defined period of time, e.g.
to switch on a light for 20 seconds.
Active/Inactive - click these buttons to
manually start and stop a connected
device, e.g. switch a light on/off.
The Trigger buttons can trigger an event directly from the Live View page.
These are configured under Setup > Live View Config > Layout.
12
AXIS 207 - Accessing the Camera
AMC audio controls
There are audio controls for controlling the client computer’s speaker output. These
controls are only available in MPEG-4 video format and when audio is enabled, see
Audio
Settings, on page 19.
Click the Mute/Sound button to switch the sound off and on.
Use the slider to control the volume. The volume can be set between 0
and 100.
The Snapshot button shows a snapshot of the video image currently being
displayed. Right-click on the video image to save it in JPEG format on your
computer. This button is primarily intended for use when the AMC viewer
toolbar is not available.
The AMC viewer toolbar (AXIS Media Control) is available in Microsoft Internet
Explorer only. It displays the following buttons:
The Play/Stop button starts and stops the live video stream.
The Snapshot button saves a snapshot of the video image currently being
displayed. The Snapshot function and the target directory for saving snapshots
can be configured from the AMC Control Applet, which can be opened from
the Windows Control Panel or by right-clicking the image in Internet Explorer.
Click the View Full Screen button to make the video image fill the entire
screen area. No other windows will be visible. Press Esc (Escape) on the
computer keyboard to exit full screen.
13
AXIS 207 - Video Streams
Video Streams
The AXIS 207 provides several different image and video stream formats. The type to use
depends on your requirements and on the properties of your network.
The Live View page in the AXIS 207 provides access to MPEG-4 and Motion JPEG video
streams, as well as to single JPEG images. Other applications and clients can also access
these video streams/images directly, without going via the Live View page.
How to stream MPEG-4
This video compression standard makes good use of bandwidth, and can provide
high-quality video streams at less than 1 Mbit/s. Note that the image settings of the
MPEG-4 stream are the same for all clients.
Deciding on the combination of protocols and methods to use depends on your viewing
requirements, and on the properties of your network. The available options in AMC are:
Unicast RTP This unicast method (RTP over UDP) should be
your first consideration for live unicast video,
especially when it is important to always have
an up-to-date video stream, even if some
images are dropped.
Unicasting is used for video-on-demand broad-
casting, so that there is no video traffic on the
network until a client connects and requests the
stream.
Note: There is a maximum of 10 simultaneous
unicast connections.
RTP over RTSP This unicast method (RTP tunneled over RTSP) is
useful as it is relatively simple to configure fire
-
walls to allow RTSP traffic.
RTP over RTSP over
HTTP
This unicast method can be used to traverse fire-
walls. Firewalls are commonly configured to
allow the HTTP protocol, thus allowing RTP to be
tunneled.
Multicast RTP This method (RTP over TCP) should be used for live multicast video. The video stream is always
up-to-date, even if some images are dropped.
Multicasting provides the most efficient usage of bandwidth when there are large numbers of clients
viewing simultaneously. A multicast broadcast cannot however, pass a network router unless the
router is configured to allow this. It is thus not possible to multicast over e.g. the Internet.
Note also that all multicast viewers count as one unicast viewer in the maximum total of 10 simulta-
neous connnections.
When the Reconnect Strategy is not enabled, AMC will negotiate with the camera to
determine exactly which transport protocol to use, in the order listed above. This order can
be changed and the options disabled, to suit any specific requirements. See also the AMC
User’s manual, available from www.axis.com/techsup
Important!
MPEG-4 is licensed technology. The AXIS 207 includes one viewing client license.
Installing additional unlicensed copies of the viewing client is prohibited. To pur
-
chase additional licenses, contact your Axis reseller.
19
AXIS 207 - Configuration
The bit rate type can be set as Variable Bit Rate (VBR) or Constant Bit Rate (CBR). VBR will
adjust the bit rate according to the images' complexity, thus using a lot of bandwidth for a
lot of activity in the image and less for lower activity in the monitored area.
Audio Settings
General
The AXIS 207 has a built-in microphone for one way MPEG-4, ISMA, 3GPP compatible
audio.
Enable audio - click the checkbox to enable Audio (disabled by default).
Note: To receive synchronized video and sound, it is recommended that the camera time is synchronized with an
NTP Server. This is enabled under System Options > Date & Time. Please refer to the help pages for more
information.
20
AXIS 207 - Live View Config
Live View Config
Layout
These are the tools for deciding the layout of the Live View page.
The layout can be set in 3 ways:
Use Axis look - the layout is unchanged.
Use custom settings - modify the Axis look, with your own colors, images etc. Click the
Configure button and see
Customizing the default page, on page 21.
Own Home Page - Upload and use your own custom page as the default web page. Click
the Configure button and see
Customizing the default page, on page 21.
The other settings on this page concern the features to include on the live view page; e.g.
action button, output button, etc. There are also settings for the default video format and
viewer. See
page 22 and the onlinge help for more information.
21
AXIS 207 - Live View Config
Customizing the default page
The appearance of the default Live
View page can be customized to suit
your own requirements, or you can
upload and use your own home page.
To upload your own files, click the
Upload/Remove button and see the
description below.
Upload Own Web Files
Your own web files, background pictures, etc., must first be uploaded to the camera in
order to be available for selection in the Custom Settings setup dialog. Once uploaded, the
files are shown in the drop-down lists.
1. Click the Upload/Remove button.
2. Enter the path to the file, e.g. a file located on your workstation or click the
Browse button.
3. Select the user level for the uploaded file. Setting the user access level means that
you have complete control over which pages can be viewed by which users.
4. When the path is shown correctly in the text field, click the Upload button.
All uploaded files are shown in the list in the lower section of the page. To remove a file,
check the box provided next to it and then click the Remove button.
Unchecking the box for Show setup link will remove the setup link from the product's
Home Page. The Setup Tools will then only be accessible by entering the full setup address
into the address/URL field of a browser.
Own Home Page
To use a previously uploaded web page as the default page, check the box, select the page
from the drop-down list and click OK.
If the setup link is hidden, setup can be reached at this url: http://<ip address>/operator/basic.shtml.
22
AXIS 207 - Live View Config
Action Buttons
The manual trigger buttons can be used to manually trigger and stop an event from the
Live View page. See
Event Configuration, on page 24.
Enabling the display of the Snapshot button allows users to save a snapshot from the
video stream by clicking the button. This button is mainly intended for use with browsers
other than Internet Explorer, or when otherwise not using AXIS Media Control (AMC) to
view the video stream. AMC (an ActiveX control) for Internet Explorer provides its own
snapshot button.
Output Buttons
The output buttons are used to manually activate the output from the Live View page, e.g.
to switch a light on and off. There are 2 options for how the output is activated:
The Pulse button activates the output for a defined period
Active/Inactive displays 2 buttons, one for each action (on/off)
Default Video Format
Select the default video format to use on the Live View page. Checking the box for Show
video format selection displays a drop-down list on the Live View page allowing you to
temporarily change the format.
When using MPEG-4 as the video format, the default viewer is AXIS Media Control with
Internet Explorer.
Note: It is also possible to view Motion JPEG when MPEG-4 is chosen as default and vice versa.
Default Viewer
From the drop-down lists, select the default method for viewing video images for your
browser. The camera will attempt to show the video images in the selected video format
and viewer. If this is not possible, the camera will override the settings and select the best
available combination.
AMC Recommended viewer in Windows Internet Explorer (MPEG-4 /Motion JPEG).
QuickTime MPEG-4 only.
Java applet A slower imaging alternative to AMC (Motion JPEG only). Requires Java download.
Still image Displays still images only. Hit the Refresh button in your browser to view a new image.
Server Push Recommended viewer for other browsers (Motion JPEG).
QuickTime MPEG-4 only.
Java applet A slower imaging alternative to Server Push (Motion JPEG only).
Still image Displays still images only. Hit the Refresh button in your browser to view a new image.
Browser Viewer Description
Windows
Internet Explorer
Other browsers
23
AXIS 207 - Live View Config
Viewer Settings
Check the Show viewer toolbar box to display e.g. the AXIS Media Control (AMC) or the
QuickTime viewer toolbar under the video image in your browser.
Enable MPEG-4 decoder installation - The installation of the MPEG-4 decoder included
with AMC can be disabled by the administrator, to prevent the installation of unlicensed
copies. Further decoder licenses can be purchased from your Axis dealer. Check the box to
enable.
Enable recording button for MPEG-4 - Enabling this button allows the user to start an
MPEG-4 recording directly from the Live View page.
HTML Examples
You can add live video from the AXIS 207 to your own web site. The camera can transmit
a Motion JPEG stream to up to 10 simultaneous connections, although an administrator
can restrict this to fewer.
Select the preferred Video Format from the drop down list. The available options are
Motion JPEG, MPEG-4 using AMC and MPEG-4 using QuickTime. If MPEG-4 is set as the
video format, note that a separate MPEG-4 license is required for each viewer.
The Motion JPEG selection has additional settings for Image Type, Image size and other
optional settings to configure the video stream to suit your Web page. Click Update once
satisfied.
The camera generates the required source code for your configuration. Copy this code and
paste it into your own Web page code.
24
AXIS 207 - Event Configuration
Event Configuration
An event in the AXIS 207 is when a trigger is activated, causing a certain action to be
performed. The event is the set of parameters (or conditions) that specifies how and when
which actions will be performed. A common event is when the camera uploads images,
triggered by an alarm.
This section describes how to configure the AXIS 207 to perform certain actions when an
event (e.g. an alarm) occurs.
Triggered by...
Input Port
This describes the state that the
input must be in for an event to
be triggered e.g. a door sensor
connected to the camera’s input
port. If the door sensor is active,
an event is triggered.
Motion Detection
Movement in a motion detection
window can be used to trigger an event. Select the motion detection window from the
drop-down list and specify whether to trigger the event when motion stops or starts. For
information on how to set up motion detection windows see
Motion Detection, on page 26.
Manual Trigger
This option makes use of the action buttons on the live view page, which are used to start
or stop the event manually, e.g. activate an alarm connected to the camera’s output port.
Alternatively the event can be triggered via the product's API (Application Programming
Interface).
When Triggered...
Upload images/video - Enabling this option allows images or video to be uploaded to
different destinations, via FTP, via HTTP, or in email messages. Check the box to enable
and select the required upload method. See the online help for more information on the
settings required for upload servers and email.
Note: Mail servers must be configured under System Options > Network > SMTP
File format - Enter the file format (MPEG-4 or JPEG) you wish to upload. Check the
Include audio checkbox if audio is to be included (MPEG-4 only).
25
AXIS 207 - Event Configuration
Include Pre-trigger and Post-trigger buffers - This function is useful when checking to see
what happened immediately before and/or after a trigger, e.g. 5 seconds before and/or after
a door was opened.
Include pre-trigger buffer - images stored internally in the camera from the time
immediately preceding the trigger. Check the box to enable the pre-trigger buffer and
enter the desired length of time (and the required image frequency if JPEG is selected).
Include post-trigger buffer - contains images from the time immediately after the trig-
ger. Configure as for pre-trigger.
Notes: •Pre-trigger and Post-trigger buffers will be lost if the connection to the mail server fails.
•Cyclic refresh must be disabled if Event handling is enabled and the file format is set to MPEG-4
See Setup > Video & Image > Advanced > MPEG-4.
•The maximum length of the pre-/post-buffer depends on the video image size
(and frame rate).
Base file name - this name will be used for all of the image files saved. If suffixes are
also used, the file name will take the form <basename><suffix>.<extension>
Add a sequence number suffix - keep track of uploaded images by assigning each
image with a number.
Use own file name format - check this radio button to use a customized file name.
Enter the file name in the Base file name field above. It is possible to perform
advanced file name formatting, by including special patterns in the file name.
Activate output port - the output port controls external equipment connected to the I/O
port on the AXIS 207, e.g. an alarm bell or light.
Send HTTP notification - This sends notification messages to an HTTP notification server
that listens for these. The destination server must first be configured from HTTP server
settings...
Send TCP notification - This sends notification messages to a TCP notification server that
listens for these. The destination server must first be configured from TCP server settings...
See the online help for more information on notification servers.
26
AXIS 207 - Event Configuration
Motion Detection
The motion detection feature is used to generate an alarm whenever movement occurs (or
stops) in the video image. A total of 10 Include and/or Exclude windows can be
configured.
Included windows target specific areas within the whole video image
Excluded windows define areas within an Include window that should be ignored
(areas outside Include windows are automatically ignored)
Once configured, the motion detection windows will appear in the list of available triggers,
for triggering events. See the section on
Event Configuration above.
Note: Using the motion detection feature may decrease the camera’s overall performance.
How to configure Motion Detection
1. Click Motion Detection in the Event Configuration menu.
2. Click the Configure Included Window radio button.
3. Click New, or if using the Java Applet, click Add Window.
4. Enter a descriptive name under Window name.
5. Adjust the size (drag the bottom right-hand corner) and position (click on the text
at the top and drag to the desired position).
6. Adjust the Object size, History and Sensitivity profile sliders (see table below for
details). Any detected motion within an active window is then indicated by red
peaks in the Activity window (the active window has a red frame).
7. Click Save.
Please see the online help for descriptions of each available option.
Object Size History Sensitivity
High level Only very large objects trig-
ger motion detection
An object that appears in the
region will trigger the motion
detection for a long period
Ordinary colored objects on ordinary back-
grounds will trigger the motion detection
Low level Even very small objects trig-
ger motion detection
An object that appears in the
region will trigger motion
detection for only a very short
period
Only very bright objects on a dark background
will trigger motion detection
Default value Low Medium to High Medium to High
To exclude parts of the Include window, click the Configure Excluded Windows button
and position the Exclude window as required, within the Include window.
53
AXIS 207 - Index
Index
Numerics
3GPP 10, 15
A
Action Buttons 22
Active/Inactive 22
Administrator 16
Alarm 26, 36
AMC 9
AMC Viewer Toolbar 12
ARP/Ping 29
Auxiliary Power 36
AXIS Internet Dynamic DNS Service 29
B
Backup 34
Bit Rate 18
Bonjour 9
Buffer Size 25
Buffers 25
C
Configuration 16
Control Button 7, 35
Customize 21
D
Date & Time 28
Default Viewer 22
DNS Configuration 29
DNS Server 29, 30
Domain Name 30
E
Emergency Recovery 39
Enable ARP/Ping 29
Events 24
F
Factory Default Settings 35
Frame Rate 18
G
GOV Settings 18
H
Host Name 30
HTML Examples 23
I
I/O Ports 33
I/O Terminal Block 7, 36
Include Windows 26
Input 36
L
Live View 11, 16
Live View Config 20
Logs & Reports 34
M
Motion Detection 24, 26, 36
MPEG-4 Settings 18
N
NAT traversal 10, 30, 31
Network Connector 7
Notification of IP address change 29
NTP Server 28
O
Output 36
Output Buttons 22
Own Home Page 21
Own Web Files 21
P
Pinout - I/O connectors 36
Port Status 27
Ports & Devices 33
Post-trigger Buffer 25
Power Connector 7
Pulse 11, 22
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Axis 207 network camera 10 pack at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Axis 207 network camera 10 pack in the language / languages: English as an attachment in your email.

The manual is 1,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info