seconds. The LED stops flashing, indicating that the resetting
of the signal has been accomplished.
Resetting the carbon filter saturation signal (ORANGE
(amber) LED FLASHING)
Note! The reset of the carbon filter saturation signal is
normally deactivated. To activate it, see under paragraph
“Activating the carbon filter saturation signal”.
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Press the “+” and “-” keys contemporaneously for about 3
seconds. The LED stops flashing, indicating that the resetting
of the signal has been accomplished.
Deactivating the carbon filter saturation signal (for
special applications)
Switch the hood off (see paragraph above “Selecting the
suction speed (power)”).
Press the "" key or the "" key until seeing the symbol
relating to the “Resetting and configuration of the filters
saturation signal” function on the remote control.
Press keys “+” and “-” contemporaneously for about 3
seconds. The LED flashes in GREEN to indicate that the
carbon filter saturation signal has been deactivated.
To reactivate the carbon filter saturation signal, repeat the
operation. The LED flashes in ORANGE.
Maintenance of the remote control
Cleaning the remote control:
Clean the remote control with a damp cloth and a neutral
solution of detergent without abrasive substances.
Changing the battery:
Open the battery casing using a small screwdriver with a
flat point.
Change the finished battery with a new one of 12 V type
MN21/23
In inserting the new battery respect the polarity indicated
on the battery casing!
Close the battery casing up again.
Disposal of the batteries
Ultimate disposal of the batteries should be handled according
to all national laws and regulations. Do not place used
batteries in your regular waste.
Ultimate disposal of the batteries must be done safely.
Contact your local waste management officials for other
information regarding the environmentally sound collection,
recycling, and disposal of the batteries.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Panel
Fig. 9-24
Clean the perimeter aspiration panel with the same frequency
as the ant-fats filter, using a cloth and not too concentrated
liquid detergent. Do not use abrasive substances.
Grease filter
Fig. 10-23
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Charcoal filter (filter version only)
Fig. 22
It absorbs unpleasant odours caused by cooking.
The saturation of the activated charcoal occurs after more or
less prolonged use, depending on the type of cooking and the
regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least
every four mounths (or when the filter saturation indication
system – if envisaged on the model in possession – indicates
this necessity).
Remove the grease filters.
Fit the charcoalfilters over the motor.
Align the pins R on the cowl with the slots S, then turn the
filter clockwise until it locks in place.
Reverse the above procedure to remove the charcoal filters.
Refit the grease filters.
Replacing lamps
Fig. 28-29
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Replacing central lamps
1. Using a flat head screwdriver or equivalent tool, carefully
pry loose the light cover.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Axiair Elica - Alba Pyramide at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Axiair Elica - Alba Pyramide in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info