Naam storing Omschrijving storing Waarneming Mogelijke oorzaak Oplossing
weergave display storing tijdens storing
F 14 Aanvoertemperatuur Zie F 5
groter dan 95 °C Weerstand installatie
te groot, bypass
onvoldoende
F 16 Foutieve vlamdetectie Gedurende korte Onvoldoende Controleer alle
tijd vlam zichtbaar, aarding aardbekabeling en zorg
valt daarna weg toestel voor goede aarding
F 17 Onvoldoende Defecte zekering Controleer de
netspanning < 170 V ~
transformator, zekering en
bedrading. Vervang de
transformator indien nodig
Defecte hoofdprint Vervang hoofdprint
F 18 Fout in user interface Vervang user interface
F 19 CV NTC (aanvoer en/of Connector los van Herstel connector
retour) onderbroken NTC
Breuk in bekabeling Vervang bekabeling
NTC defect Vervang NTC
F 20 Software niet compatible Neem contact op met de
servicedienst van AWB
F 21 Waterdruksysteem te laag Lekkage in de Lekkage opsporen
installaltie of (expansievat) en
verhelpen
Expansievat defect
F 22 Waterdruksysteem Defect expansievat Expansievat controleren
te hoog Systeem te hoog en eventueel vervangen
in druk gevuld Druk aflaten
F 24 Retourtemperatuur Onvoldoende Zie F 5
> 90 °C circulatie of Weerstand installatie te
groot, bypass
Geen circulatie onvoldoende
F 25 Te snelle stijging aanvoer- Zie F 5
temperatuur Weerstand installatie
te groot, bypass
onvoldoende
F 26 Te groot temperatuurs- Zie F 5
verschil tussen aanvoer- en Weerstand installatie te
retourtemperatuur in groot, bypass
cv mode onvoldoende
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AWB Thermomaster HRG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AWB Thermomaster HRG in the language / languages: Dutch as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AWB Thermomaster HRG

AWB Thermomaster HRG Manual - Dutch - 2 pages

AWB Thermomaster HRG Installation Guide - Dutch - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info