VERGRENDELENDE STORINGEN, STORINGSTABEL
Naam storing Omschrijving storing Waarneming Mogelijke oorzaak Oplossing
weergave display storing tijdens storing
11 Geen signaal Controleer bedrading en
op hoofdboard user interface.
Indien in orde vervang
dan het hoofdboard
Ventilator defect Vervang ventilator
12 Geen signaal Controleer bedrading en
op user interface hoofdboard. Indien in orde
vervang dan de user interface
13 Verkeerde boilerinstelling Controleer parameter 23
parameter
Hoofdboard fout Vervang hoofdboard
14 Aanvoertemperatuur Zie F 05
groter dan 95°C Weerstand installatie te groot,
bypass onvoldoende
15 Fout in stappenmotor Controleer bedrading.
driewegklep Indien in orde vervang dan de
driewegklep
16 Foutieve vlamdetectie Gedurende korte Onvoldoende Controleer alle
tijd vlam zichtbaar, aarding toestel aardbekabeling en zorg
valt daarna weg voor goede aarding
17 Onvoldoende Defecte zekering Controleer de
netspanning < 170 V ~ transformator, zekering
en bedrading. Vervang de
transformator indien nodig
Defecte hoofdprint Vervang hoofdprint
18 (geen wijziging)
19 Aanvoer NTC fout, Controleer bevestiging van
10 keer na elkaar dT > 35K aaanvoer temperatuur.
Controleer bypass
20 Software niet compatible Neem contact op met de
servicedienst van AWB
21 Waterdruk systeem te laag Lekkage in de Lekkage opsporen
installaltie of (expansievat) en verhelpen
expansievat defect
22 Waterdruk systeem te hoog Defect expansievat. Expansievat controleren
Systeem te hoog en eventueel vervangen
in druk gevuld Druk aflaten
24 Retour temperatuur > 90°C Onvoldoende Zie F 05
circulatie of Weerstand installatie te groot,
geen circulatie bypass onvoldoende
25 Te snelle stijging Zie F 05
aanvoertemperatuur Weerstand installatie te groot,
bypass onvoldoende
26 Te groot Zie F 05
temperatuursverschil Weerstand installatie te
tussen aanvoer- en groot, bypass onvoldoende
retourtemperatuur in
cv-mode
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AWB ThermoElegance 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AWB ThermoElegance 6 in the language / languages: Dutch as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AWB ThermoElegance 6

AWB ThermoElegance 6 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info