Technical Specifications
4 Technical Specifications
4.1 Jumper Positions for I/O Address
Selection
To install the Controller it may be necessary to change
the I/O address from the factory setting of 300, for
instance, if other hardware components use this ad-
dress.
The I/O address is changed by moving a jumper on the
ISDN-Controller card, then entering the new address in
the ISDN-Controller driver software or operating system
configuration. This section describes the hardware
adjustment: moving the jumper. The procedure for
adjusting the software configuration is described for
each operating system in Chapter 3, Driver Software
Installation.
The ISDN-Controller has one jumper row containing one
jumper. To locate the jumper row, hold the board in front
of you with the component side up. The controller
sockets are at the right side, the contact fingers are at
the bottom (see illustration):
Jumper
slot blanking
plate
socket for the
ISDN cable
Figure 8 AVM ISDN-Controller A1
The position of the jumper determines the I/O address.
The following diagrams show the jumper settings and the
corresponding I/O addresses. To change the I/O ad-
dress, pull the jumper off and slide it onto the contacts at
the corresponding position.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AVM ISDN-Controller A1 v3.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AVM ISDN-Controller A1 v3.0 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of AVM ISDN-Controller A1 v3.0

AVM ISDN-Controller A1 v3.0 User Manual - German - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info